|
Abraham, D., Colussi, V., Shina, D., Kinsella, T., & Sibata, C. (2000). TBI treatment planning using the ADAC pinnacle treatment planning system. Med Dosim, 25(4), 219-224. Aruga, T., Itami, J., Aruga, M., Nakajima, K., Shibata, K., Nojo, T., . . . Ito, H. (2000). Target volume definition for upper abdominal irradiation using CT scans obtained during inhale and exhale phases. Int J Radiat Oncol Biol Phys, 48(2), 465-469. Balter, J. M., Wright, J. N., Newell, L. J., Friemel, B., Dimmer, S., Cheng, Y., . . . Mate, T. P. (2005). Accuracy of a wireless localization system for radiotherapy. Int J Radiat Oncol Biol Phys, 61(3), 933-937. doi: 10.1016/j.ijrobp.2004.11.009 Breneman, J. C., Elson, H. R., Little, R., Lamba, M., Foster, A. E., & Aron, B. S. (1990). A technique for delivery of total body irradiation for bone marrow transplantation in adults and adolescents. Int J Radiat Oncol Biol Phys, 18(5), 1233-1236. Chao, M., Penagaricano, J., Yan, Y., Moros, E. G., Corry, P., & Ratanatharathorn, V. (2012). Voxel-based dose reconstruction for total body irradiation with helical tomotherapy. Int J Radiat Oncol Biol Phys, 82(5), 1575-1583. doi: 10.1016/j.ijrobp.2011.01.021 Chen, Ho-Hsing, Wu, Jay, Chuang, Keh-Shih, & Kuo, Hsiang-Chi. (2007). Correction of respiratory motion for IMRT using aperture adaptive technique and visual guidance: A feasibility study. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 577(3), 734-740. doi: http://dx.doi.org/10.1016/j.nima.2007.04.122 Chen, Q. S., Weinhous, M. S., Deibel, F. C., Ciezki, J. P., & Macklis, R. M. (2001). Fluoroscopic study of tumor motion due to breathing: facilitating precise radiation therapy for lung cancer patients. Med Phys, 28(9), 1850-1856. Chretien, M., Cote, C., Blais, R., Brouard, L., Roy-Lacroix, L., Larochelle, M., . . . Pouliot, J. (2000). A variable speed translating couch technique for total body irradiation. Med Phys, 27(5), 1127-1130. Chui, C. S., Fontenla, D. P., Mullokandov, E., Kapulsky, A., Lo, Y. C., & Lo, C. J. (1997). Total body irradiation with an arc and a gravity-oriented compensator. Int J Radiat Oncol Biol Phys, 39(5), 1191-1195. Chui, C. S., Yorke, E., & Hong, L. (2003). The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator. Med Phys, 30(7), 1736-1746. Collins, B. T., Vahdat, S., Erickson, K., Collins, S. P., Suy, S., Yu, X., . . . Anderson, E. D. (2009). Radical cyberknife radiosurgery with tumor tracking: an effective treatment for inoperable small peripheral stage I non-small cell lung cancer. J Hematol Oncol, 2, 1. doi: 10.1186/1756-8722-2-1 D'Souza, W. D., & McAvoy, T. J. (2006). An analysis of the treatment couch and control system dynamics for respiration-induced motion compensation. Med Phys, 33(12), 4701-4709. Duan, J., Shen, S., Fiveash, J. B., Popple, R. A., & Brezovich, I. A. (2006). Dosimetric and radiobiological impact of dose fractionation on respiratory motion induced IMRT delivery errors: a volumetric dose measurement study. Med Phys, 33(5), 1380-1387. Duan, J., Shen, S., Spencer, S. A., Ahmed, R. S., Popple, R. A., Ye, S. J., & Brezovich, I. A. (2004). A dynamic supraclavicular field-matching technique for head-and-neck cancer patients treated with IMRT. Int J Radiat Oncol Biol Phys, 60(3), 959-972. doi: 10.1016/j.ijrobp.2004.06.213 Ford, E. C., Mageras, G. S., Yorke, E., & Ling, C. C. (2003). Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning. Med Phys, 30(1), 88-97. Giraud, Philippe, Yorke, Ellen, Ford, Eric C., Wagman, Raquel, Mageras, Gig S., Amols, Howard, . . . Rosenzweig, Kenneth E. (2006). Reduction of organ motion in lung tumors with respiratory gating. Lung Cancer, 51(1), 41-51. Hara, R., Itami, J., Kondo, T., Aruga, T., Abe, Y., Ito, M., . . . Kobiki, T. (2002). Stereotactic single high dose irradiation of lung tumors under respiratory gating. Radiother Oncol, 63(2), 159-163. Held, M., Kirby, N., Morin, O., & Pouliot, J. (2012). Dosimetric aspects of inverse-planned modulated-arc total-body irradiation. Med Phys, 39(8), 5263-5271. doi: 10.1118/1.4739250 Hong, L., Alektiar, K., Chui, C., LoSasso, T., Hunt, M., Spirou, S., . . . Leibel, S. (2002). IMRT of large fields: whole-abdomen irradiation. Int J Radiat Oncol Biol Phys, 54(1), 278-289. Hoogeman, M., Prevost, J. B., Nuyttens, J., Poll, J., Levendag, P., & Heijmen, B. (2009). Clinical accuracy of the respiratory tumor tracking system of the cyberknife: assessment by analysis of log files. Int J Radiat Oncol Biol Phys, 74(1), 297-303. doi: 10.1016/j.ijrobp.2008.12.041 Hugo, G. D., Agazaryan, N., & Solberg, T. D. (2003). The effects of tumor motion on planning and delivery of respiratory-gated IMRT. Med Phys, 30(6), 1052-1066. Hui, S. K., Das, R. K., Thomadsen, B., & Henderson, D. (2004). CT-based analysis of dose homogeneity in total body irradiation using lateral beam. J Appl Clin Med Phys, 5(4), 71-79. Hussain, A., Dunscombe, P., Villarreal-Barajas, J. E., & Brown, D. (2012). Total body irradiation dose optimization based on radiological depth. J Appl Clin Med Phys, 13(3), 3767. doi: 10.1120/jacmp.v13i3.3767 Hussain, A., Villarreal-Barajas, J. E., Dunscombe, P., & Brown, D. W. (2011). Aperture modulated, translating bed total body irradiation. Med Phys, 38(2), 932-941. J. Van Dyk, Chairman, & Galvin, J. M. (1986). THE PHYSICAL ASPECTS OF TOTAL AND HALF BODYPHOTON IRRADIATION. 335 E. 45 Street New York. NY 10017: American Association of Physicists in Medicine by the American institute of Physics. Keall, P. J., Kini, V. R., Vedam, S. S., & Mohan, R. (2001). Motion adaptive x-ray therapy: a feasibility study. Phys Med Biol, 46(1), 1-10. Keall, P. J., Mageras, G. S., Balter, J. M., Emery, R. S., Forster, K. M., Jiang, S. B., . . . Yorke, E. (2006). The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys, 33(10), 3874-3900. Keall, Paul J., Mageras, Gig S., Balter, James M., Emery, Richard S., Forster, Kenneth M., Jiang, Steve B., . . . Yorke, Ellen. (2006). The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Medical Physics, 33(10), 3874-3900. Khan, Faiz M, & Khan, FM. (2010). The physics of radiation therapy (Vol. 4): Lippincott Williams & Wilkins Philadelphia. Kim, D. J., Murray, B. R., Halperin, R., & Roa, W. H. (2001). Held-breath self-gating technique for radiotherapy of non-small-cell lung cancer: a feasibility study. Int J Radiat Oncol Biol Phys, 49(1), 43-49. Kirby, N., Held, M., Morin, O., Fogh, S., & Pouliot, J. (2012). Inverse-planned modulated-arc total-body irradiation. Med Phys, 39(5), 2761-2764. doi: 10.1118/1.4705366 Kubo, H. D., & Hill, B. C. (1996). Respiration gated radiotherapy treatment: a technical study. Phys Med Biol, 41(1), 83-91. Lagerwaard, F. J., Van Sornsen de Koste, J. R., Nijssen-Visser, M. R., Schuchhard-Schipper, R. H., Oei, S. S., Munne, A., & Senan, S. (2001). Multiple "slow" CT scans for incorporating lung tumor mobility in radiotherapy planning. Int J Radiat Oncol Biol Phys, 51(4), 932-937. Landberg, T, Chavaudra, J, & Dobbs, J. (1993). ICRU (International Commission of Radiation Units and Measurements) Report No. 50: Prescribing, Recording, and Reporting Photon Beam Therapy. International Commission of Radiation Units and Measurements, Washington, DC. Lavallee, M. C., Aubin, S., Chretien, M., Larochelle, M., & Beaulieu, L. (2008). Attenuator design for organs at risk in total body irradiation using a translation technique. Med Phys, 35(5), 1663-1669. Lavallee, M. C., Aubin, S., Larochelle, M., Vallieres, I., & Beaulieu, L. (2011). 3D heterogeneous dose distributions for total body irradiation patients. J Appl Clin Med Phys, 12(3), 3416. Lavallee, M. C., Gingras, L., Chretien, M., Aubin, S., Cote, C., & Beaulieu, L. (2009). Commissioning and evaluation of an extended SSD photon model for PINNACLE3: an application to total body irradiation. Med Phys, 36(8), 3844-3855. LoSasso, T., Chui, C. S., & Ling, C. C. (1998). Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy. Med Phys, 25(10), 1919-1927. Lu, W., Parikh, P. J., El Naqa, I. M., Nystrom, M. M., Hubenschmidt, J. P., Wahab, S. H., . . . Low, D. A. (2005). Quantitation of the reconstruction quality of a four-dimensional computed tomography process for lung cancer patients. Med Phys, 32(4), 890-901. Lujan, A. E., Larsen, E. W., Balter, J. M., & Ten Haken, R. K. (1999). A method for incorporating organ motion due to breathing into 3D dose calculations. Med Phys, 26(5), 715-720. Mah, D., Hanley, J., Rosenzweig, K. E., Yorke, E., Braban, L., Ling, C. C., . . . Mageras, G. (2000). Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer. Int J Radiat Oncol Biol Phys, 48(4), 1175-1185. Malone, S., Crook, J. M., Kendal, W. S., & Szanto, J. (2000). Respiratory-induced prostate motion: quantification and characterization. Int J Radiat Oncol Biol Phys, 48(1), 105-109. McMahon, R., Berbeco, R., Nishioka, S., Ishikawa, M., & Papiez, L. (2008). A real-time dynamic-MLC control algorithm for delivering IMRT to targets undergoing 2D rigid motion in the beam's eye view. Med Phys, 35(9), 3875-3888. Miralbell, R., Rouzaud, M., Grob, E., Nouet, P., Bieri, S., Majno, S. B., . . . Precoma, J. C. (1994). Can a total body irradiation technique be fast and reproducible? Int J Radiat Oncol Biol Phys, 29(5), 1167-1173. Molloy, J. A. (2010). Statistical analysis of dose heterogeneity in circulating blood: implications for sequential methods of total body irradiation. Med Phys, 37(11), 5568-5578. Murphy, Martin J. (2004). Tracking moving organs in real time. Seminars in Radiation Oncology, 14(1), 91-100. Negoro, Y., Nagata, Y., Aoki, T., Mizowaki, T., Araki, N., Takayama, K., . . . Hiraoka, M. (2001). The effectiveness of an immobilization device in conformal radiotherapy for lung tumor: reduction of respiratory tumor movement and evaluation of the daily setup accuracy. Int J Radiat Oncol Biol Phys, 50(4), 889-898. Neicu, T., Shirato, H., Seppenwoolde, Y., & Jiang, S. B. (2003). Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients. Phys Med Biol, 48(5), 587-598. Onal, C., Sonmez, A., Arslan, G., Sonmez, S., Efe, E., & Oymak, E. (2012). Evaluation of Field-in-Field Technique for Total Body Irradiation. Int J Radiat Oncol Biol Phys, 83(5), 1641-1648. doi: 10.1016/j.ijrobp.2011.10.045 Onimaru, R., Shirato, H., Fujino, M., Suzuki, K., Yamazaki, K., Nishimura, M., . . . Miyasaka, K. (2005). The effect of tumor location and respiratory function on tumor movement estimated by real-time tracking radiotherapy (RTRT) system. Int J Radiat Oncol Biol Phys, 63(1), 164-169. doi: 10.1016/j.ijrobp.2005.01.025 Pan, T., Lee, T. Y., Rietzel, E., & Chen, G. T. (2004). 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. Med Phys, 31(2), 333-340. Papiez, L., McMahon, R., & Timmerman, R. (2007). 4D DMLC leaf sequencing to minimize organ at risk dose in moving anatomy. Med Phys, 34(12), 4952-4956. Papiez, L., Rangaraj, D., & Keall, P. (2005). Real-time DMLC IMRT delivery for mobile and deforming targets. Med Phys, 32(9), 3037-3048. Papieza, L. (2004). DMLC leaf-pair optimal control of IMRT delivery for a moving rigid target. Med Phys, 31(10), 2742-2754. Pepin, E. W., Wu, H., Zhang, Y., & Lord, B. (2011). Correlation and prediction uncertainties in the cyberknife synchrony respiratory tracking system. Med Phys, 38(7), 4036-4044. Popple, R. A., & Brezovich, I. A. (2011). Dynamic MLC leaf sequencing for integrated linear accelerator control systems. Med Phys, 38(11), 6039-6045. doi: 10.1118/1.3651628 Ramsey, C. R., Scaperoth, D., Arwood, D., & Oliver, A. L. (1999). Clinical efficacy of respiratory gated conformal radiation therapy. Med Dosim, 24(2), 115-119. Remouchamps, V. M., Letts, N., Vicini, F. A., Sharpe, M. B., Kestin, L. L., Chen, P. Y., . . . Wong, J. W. (2003). Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy. Int J Radiat Oncol Biol Phys, 56(3), 704-715. Remouchamps, V. M., Letts, N., Yan, D., Vicini, F. A., Moreau, M., Zielinski, J. A., . . . Wong, J. W. (2003). Three-dimensional evaluation of intra- and interfraction immobilization of lung and chest wall using active breathing control: a reproducibility study with breast cancer patients. Int J Radiat Oncol Biol Phys, 57(4), 968-978. Remouchamps, V. M., Vicini, F. A., Sharpe, M. B., Kestin, L. L., Martinez, A. A., & Wong, J. W. (2003). Significant reductions in heart and lung doses using deep inspiration breath hold with active breathing control and intensity-modulated radiation therapy for patients treated with locoregional breast irradiation. Int J Radiat Oncol Biol Phys, 55(2), 392-406. Rosenzweig, K. E., Hanley, J., Mah, D., Mageras, G., Hunt, M., Toner, S., . . . Leibel, S. A. (2000). The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer. Int J Radiat Oncol Biol Phys, 48(1), 81-87. Schaeken, B., Lelie, S., Meijnders, P., Van den Weyngaert, D., Janssens, H., & Verellen, D. (2010). Alanine/EPR dosimetry applied to the verification of a total body irradiation protocol and treatment planning dose calculation using a humanoid phantom. Med Phys, 37(12), 6292-6299. Schultheiss, T. E., Wong, J., Liu, A., Olivera, G., & Somlo, G. (2007). Image-guided total marrow and total lymphatic irradiation using helical tomotherapy. Int J Radiat Oncol Biol Phys, 67(4), 1259-1267. doi: 10.1016/j.ijrobp.2006.10.047 Schweikard, A., Glosser, G., Bodduluri, M., Murphy, M. J., & Adler, J. R. (2000). Robotic motion compensation for respiratory movement during radiosurgery. Comput Aided Surg, 5(4), 263-277. doi: 10.1002/1097-0150(2000)5:4<263::AID-IGS5>3.0.CO;2-2 Seiler, P. G., Blattmann, H., Kirsch, S., Muench, R. K., & Schilling, C. (2000). A novel tracking technique for the continuous precise measurement of tumour positions in conformal radiotherapy. Phys Med Biol, 45(9), N103-110. Seppenwoolde, Y., Shirato, H., Kitamura, K., Shimizu, S., van Herk, M., Lebesque, J. V., & Miyasaka, K. (2002). Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys, 53(4), 822-834. Sharma, M., Dos Santos, T., Papanikolopoulos, N. P., & Hui, S. K. (2011). Feasibility of intrafraction whole-body motion tracking for total marrow irradiation. J Biomed Opt, 16(5), 058002. doi: 10.1117/1.3575645 Sharp, G. C., Jiang, S. B., Shimizu, S., & Shirato, H. (2004). Prediction of respiratory tumour motion for real-time image-guided radiotherapy. Phys Med Biol, 49(3), 425-440. Shimizu, S., Shirato, H., Kagei, K., Nishioka, T., Bo, X., Dosaka-Akita, H., . . . Miyasaka, K. (2000). Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy. Int J Radiat Oncol Biol Phys, 46(5), 1127-1133. Shirato, H., Oita, M., Fujita, K., Watanabe, Y., & Miyasaka, K. (2004). Feasibility of synchronization of real-time tumor-tracking radiotherapy and intensity-modulated radiotherapy from viewpoint of excessive dose from fluoroscopy. Int J Radiat Oncol Biol Phys, 60(1), 335-341. doi: 10.1016/j.ijrobp.2004.04.028 Shirato, H., Shimizu, S., Kitamura, K., Nishioka, T., Kagei, K., Hashimoto, S., . . . Miyasaka, K. (2000). Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. Int J Radiat Oncol Biol Phys, 48(2), 435-442. Shirato, H., Shimizu, S., Kunieda, T., Kitamura, K., van Herk, M., Kagei, K., . . . Miyasaka, K. (2000). Physical aspects of a real-time tumor-tracking system for gated radiotherapy. Int J Radiat Oncol Biol Phys, 48(4), 1187-1195. Siebers, J. V., Lauterbach, M., Keall, P. J., & Mohan, R. (2002). Incorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization. Med Phys, 29(6), 952-959. Spirou, S. V., & Chui, C. S. (1994). Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators. Med Phys, 21(7), 1031-1041. Spirou, S. V., & Chui, C. S. (1996). Generation of arbitrary intensity profiles by combining the scanning beam with dynamic multileaf collimation. Med Phys, 23(1), 1-8. Starkschall, G., Forster, K. M., Kitamura, K., Cardenas, A., Tucker, S. L., & Stevens, C. W. (2004). Correlation of gross tumor volume excursion with potential benefits of respiratory gating. Int J Radiat Oncol Biol Phys, 60(4), 1291-1297. doi: 10.1016/j.ijrobp.2004.07.707 Stein, A., & Forman, S. J. (2008). Allogeneic transplantation for ALL in adults. Bone Marrow Transplant, 41(5), 439-446. doi: 10.1038/bmt.2008.1 Ten Haken, R. K., Balter, J. M., Marsh, L. H., Robertson, J. M., & Lawrence, T. S. (1997). Potential benefits of eliminating planning target volume expansions for patient breathing in the treatment of liver tumors. Int J Radiat Oncol Biol Phys, 38(3), 613-617. Trofimov, A., Rietzel, E., Lu, H. M., Martin, B., Jiang, S., Chen, G. T., & Bortfeld, T. (2005). Temporo-spatial IMRT optimization: concepts, implementation and initial results. Phys Med Biol, 50(12), 2779-2798. doi: 10.1088/0031-9155/50/12/004 Tsunashima, Yoshikazu, Sakae, Takeji, Shioyama, Yoshiyuki, Kagei, Kenji, Terunuma, Toshiyuki, Nohtomi, Akihiro, & Akine, Yasuyuki. (2004). Correlation between the respiratory waveform measured using a respiratory sensor and 3D tumor motion in gated radiotherapy. International Journal of Radiation Oncology*Biology*Physics, 60(3), 951-958. Umek, B., Zwitter, M., & Habic, H. (1996). Total body irradiation with translation method. Radiother Oncol, 38(3), 253-255. Underberg, R. W., Lagerwaard, F. J., Slotman, B. J., Cuijpers, J. P., & Senan, S. (2005). Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer. Int J Radiat Oncol Biol Phys, 63(1), 253-260. doi: 10.1016/j.ijrobp.2005.05.045 Vedam, S., Docef, A., Fix, M., Murphy, M., & Keall, P. (2005). Dosimetric impact of geometric errors due to respiratory motion prediction on dynamic multileaf collimator-based four-dimensional radiation delivery. Med Phys, 32(6), 1607-1620. Vedam, S. S., Keall, P. J., Docef, A., Todor, D. A., Kini, V. R., & Mohan, R. (2004). Predicting respiratory motion for four-dimensional radiotherapy. Med Phys, 31(8), 2274-2283. Vedam, S. S., Keall, P. J., Kini, V. R., & Mohan, R. (2001). Determining parameters for respiration-gated radiotherapy. Med Phys, 28(10), 2139-2146. Wambersie, A, & Landgerg, T. (1999). ICRU Report 62: Prescribing, Recording and Reporting Photon Beam Therapy. ICRU Publication, Bethesda (MD). Wilkie, J. R., Tiryaki, H., Smith, B. D., Roeske, J. C., Radosevich, J. A., & Aydogan, B. (2008). Feasibility study for linac-based intensity modulated total marrow irradiation. Med Phys, 35(12), 5609-5618. Wilson, E. M., Williams, F. J., Lyn, B. E., Wong, J. W., & Aird, E. G. (2003). Validation of active breathing control in patients with non-small-cell lung cancer to be treated with CHARTWEL. Int J Radiat Oncol Biol Phys, 57(3), 864-874. Wong, J. W., Sharpe, M. B., Jaffray, D. A., Kini, V. R., Robertson, J. M., Stromberg, J. S., & Martinez, A. A. (1999). The use of active breathing control (ABC) to reduce margin for breathing motion. Int J Radiat Oncol Biol Phys, 44(4), 911-919. Wu, Q., Arnfield, M., Tong, S., Wu, Y., & Mohan, R. (2000). Dynamic splitting of large intensity-modulated fields. Phys Med Biol, 45(7), 1731-1740. Xia, P., & Verhey, L. J. (1998). Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments. Med Phys, 25(8), 1424-1434. Xu, J., Papanikolaou, N., Shi, C., & Jiang, S. B. (2009). Synchronized moving aperture radiation therapy (SMART): superimposing tumor motion on IMRT MLC leaf sequences under realistic delivery conditions. Phys Med Biol, 54(16), 4993-5007. doi: 10.1088/0031-9155/54/16/010 Yao, R., Bernard, D., Turian, J., Abrams, R. A., Sensakovic, W., Fung, H. C., & Chu, J. C. (2012). A simplified technique for delivering total body irradiation (TBI) with improved dose homogeneity. Med Phys, 39(4), 2239-2248. doi: 10.1118/1.3697526 Yeginer, M., Roeske, J. C., Radosevich, J. A., & Aydogan, B. (2011). Linear accelerator-based intensity-modulated total marrow irradiation technique for treatment of hematologic malignancies: a dosimetric feasibility study. Int J Radiat Oncol Biol Phys, 79(4), 1256-1265. doi: 10.1016/j.ijrobp.2010.06.029 Zhang, T., Jeraj, R., Keller, H., Lu, W., Olivera, G. H., McNutt, T. R., . . . Paliwal, B. (2004). Treatment plan optimization incorporating respiratory motion. Med Phys, 31(6), 1576-1586. Zhuang, A. H., Liu, A., Schultheiss, T. E., & Wong, J. Y. (2010). Dosimetric study and verification of total body irradiation using helical tomotherapy and its comparison to extended SSD technique. Med Dosim, 35(4), 243-249. doi: 10.1016/j.meddos.2009.07.001 Zygmanski, P., Kung, J. H., Jiang, S. B., & Chin, L. (2003). Dependence of fluence errors in dynamic IMRT on leaf-positional errors varying with time and leaf number. Med Phys, 30(10), 2736-2749.
|