This study was an exploratory investigation into the effects of some features of control on hand-blind-positioning performance. Its purpose was to investigated: (1) the interval, needed to discriminate the orientation, between control and a referent origin and control''s location effect on such interval; (2) the effect of push-button width on the accuracy of button-site- recognition; and (3) the effect of knob diameter on the accuracy of turned-angle-determination.Therefore, the research was composed of three experiments. Thirty right-handed subjects participated three experiments under blind condition by wearing eyeshade. The performance criteria were, respectively, the shortest interval needed (or interval threshold) for orientation-discrimination, and the absolute as well as relative deviation magnitudes by key number and angle degrees for button- site-recognition and turned-angle-determination.Results of the study shown that: (1) the difference of interval thresholds of two controls location at the same horizontal workplane was not significant; (2) the interval thresholds at north-east and south-east directions traveled by hand with elbow joint as pivot were very significantly shorter than those at north-west and south-east directions forward by forearm axis; (3) some subjects misorientated in a systematic way in certain directions; (4) the interval threshold for orientation-discrimination was on
|