[1]Li, B. N., Chui, C. K., Chang, S., and Ong, S. H., “Integrating spatial fuzzy clustering with level set methods for automated medical image segmentation,” Computers in Biology and Medi-cine, Vol. 41, No. 1, pp. 1-10, 2011.
[2]Ma, Z., Tavares, J. M. R. S., Jorge, R. N., and Mascarenhas, T., “A review of algorithms for medical image segmentation and their applications to the female pelvic cavity,” Computer Methods in Biomechanics and Biomedical Engineering, Vol. 13, No. 2, pp. 235-246, 2010.
[3]Phipps, L. M., Raymond, J. A., and Angeletti, T. M., “Congenital tracheal stenosis,” Critical Care Nurse, Vol. 26, No. 3, pp. 60-69, 2006.
[4]Ma, B., Ge, Y. H., Shi, D. P., and Guo, Y., “Application value of MSCT coronal scan and post-processing techniques to foreign body in trachea and bronchus of children,” Chinese Journal of Medical Imaging Technology, Vol. 24, No. 9, pp. 1421-1423, 2008.
[5]Ant&;oacute;n-Pacheco, J. L., Kaliciński, P., Kansy, A., and Maruszewski, P., “Slide tracheoplasty in an infant with congenital tracheal ste-nosis and oesophageal atresia with tracheoesophageal fistula,” European Journal of Cardio-thoracic Surgery, Vol. 42, No. 5, pp. 892-893, 2012.
[6]Maeda, K., Ono, S., Tazuke, Y., and Baba, K., “Long-term out-comes of congenital tracheal stenosis treated by metallic airway stenting,” Journal of Pediatric Surgery, Vol. 48, No. 2, pp. 293-296, 2013.
[7]Lawton, B., and Gungor, A., “Airway salvation after failed ante-rior graft in a child with long segment stenosis,” American Journal of Otolaryngology - Head and Neck Medicine and Surgery, Vol. 34, No. 5, pp. 606-607, 2013.
[8]Cotton, R. T., “Pediatric laryngotracheal stenosis,” Journal of Pediatric Surgery, Vol. 19, No. 6, pp. 699-704, 1984.
[9]Gustafson, L. M., Hartley, B. E., Cotton, R. T., “Acquired total (grade 4) subglottic stenosis in children,” Ann Otol Rhinol Lar-yngol, Vol. 110, No. 1, pp. 16-19, 2001.
[10]DaCruz, D. J., Taylor, R. H., Savage, B., and Bodiwala, G. G., “Ultrasound assessment of the suspected scaphoid fracture,” Ar-chives of Emergency Medicine, Vol. 5, No. 2, pp. 97-100, 1988.
[11]Goulding, A., Jones, I. E., Taylor, R. W., Williams, S. M., and Manning, P. J., “Bone mineral density and body composition in boys with distal forearm fractures: A dual-energy x-ray absorp-tiometry study,” Journal of Pediatrics, Vol. 139, No. 4, pp. 509-515, 2001.
[12]Lu, D. S. K., Reber, H. A., Krasny, R. M., Kadell, B. M., and Sayre, J., “Local staging of pancreatic cancer: Criteria for unre-sectability of major vessels as revealed by pancreatic-phase, thin-section helical CT,” American Journal of Roentgenology, Vol. 168, No. 6, pp. 1439-1443, 1997.
[13]Mattes, D., Haynor, D. R., Vesselle, H., Lewellen, T. K., and Eu-bank, W., “PET-CT image registration in the chest using free-form deformations,” IEEE Transactions on Medical Imaging, Vol. 22, No. 1, pp. 120-128, 2003.
[14]Dzikn-Jurasz, A., Domenig, C., George, M., Wolber, J., Padhani, A., Brown, G., and Doran, S., “Diffusion MRI for prediction of response of rectal cancer to chemoradiation,” the Lancet, Vol. 360, No. 9329, pp. 307-308, 2002.
[15]Rajaei, A., Lalitha, R., and Dallalzadeh, E., “Medical Image Tex-ture Segmentation Usingrange Filter,” Computer Science and In-formation Technology, Vol. 2, No. 1, pp. 273-280, 2012.
[16]Zeng, H., Liu, Y. Z., Fan, Y. M., and Tang, X., “An Improved Algorithm for Impulse Noise by Median Filter,” AASRI Procedia, Vol. 1, pp. 68-73, 2012.
[17]Hsieh, M. H., Cheng, F. C., Shie, M. C., and Ruan, S. J., “Fast and efficient median filter for removing 1-99% levels of salt-and-pepper noise in images,” Engineering Applications of Artificial Intelligence, Vol. 26, No. 4, pp. 1333-1338, 2013.
[18]Zhang, J., “An efficient median filter based method for removing random-valued impulse noise,” Digital Signal Processing: A Re-view Journal Vol. 20, No. 4, pp. 1010-1018, 2010.
[19]Hwang, H., and Haddad, R. A., “Adaptive median filters: new algorithms and results,” IEEE Transactions on Image Processing, Vol. 4, No. 4, pp. 499-502, 1995.
[20]Nair, M. S., and Ameera-Mol, P. M., “Direction based adaptive weighted switching median filter for removing high density im-pulse noise,” Computers and Electrical Engineering, Vol. 39, No. 2, pp. 663-689, 2013.
[21]Lu, C. T., and Chou, T. C., “Denoising of salt-and-pepper noise corrupted image using modified directional-weighted-median fil-ter,” Pattern Recognition Letters, Vol. 33, No. 10, pp. 1287-1295, 2012.
[22]Bao, P., and Zhang, L., “Noise Reduction for Magnetic Resonance Images via Adaptive Multiscale Products Thresholding,” IEEE Transactions on Medical Imaging, Vol. 22, No. 9, pp. 1089-1099, 2003.
[23]Srinivasan, K. S., and Ebenezer, D., “A new fast and efficient de-cision-based algorithm for removal of high-density impulse nois-es,” IEEE Signal Processing Letters, Vol. 14, No. 3, pp. 189-192, 2007.
[24]M&;eacute;lange, T., Nachtegael, M., Schulte, S., and Kerre, E. E., “A fuzzy filter for the removal of random impulse noise in image sequences,” Image and Vision Computing, Vol. 29, No. 6, pp. 407-419, 2011.
[25]Horng, S. J., Hsu, L. Y., Li, T., Qiao, S., Gong, X., Chou, H. H., and Khan, M. K., “Using sorted switching median filter to remove high-density impulse noises,” Journal of Visual Communication and Image Representation, Vol. 24, No. 7, pp. 956-967, 2013.
[26]Weibel E. R., “Morphometry of the Human Lung,” Spring-er-Verlag, Berlin, 1983.
[27]Kitaoka, H., Takaki, R., and Suki, B., “A three-dimensional model of the human airway tree,” Journal of Applied Physiology, Vol. 87, No. 6, pp. 2207-2217, 1999.
[28]Schwab, R. J., Pasirstein, M., Pierson, R., Mackley, A., Hacha-doorian, R., Arens, R., Maislin, G., and Pack, A. I., “Identification of upper airway anatomic risk factors for obstructive sleep apnea with volumetric magnetic resonance imaging,” American Journal of Respiratory and Critical Care Medicine, Vol. 168, No. 5, pp. 522-530, 2003.
[29]Aykac, D., Huffman, E. A., McLennan, G., and Reinhardt, J. M., “Segmentation and analysis of the human airway tree from three-dimensional X-ray CT images,” IEEE Transactions on Medical Imaging, Vol. 22, No. 8, pp. 940-950, 2003.
[30]Osher, S., and Sethian, J. A., “Fronts propagating with curva-ture-dependent speed: Algorithms based on Hamilton-Jacobi formulations,” Journal of Computational Physics, Vol. 79, No. 1, pp. 12-49, 1988.
[31]Kichenassamy, S., Kumar, A., Olver, P., Tannenbaum, A., and Yezzi, A., “Gradient flows and geometric active contour models,” Proceedings of the 5th International Conference on Computer Vi-sion, pp. 810-815, Cambridge, MA, USA, 1995.
[32]Chan, T. F., and Vese, L. A., “Active contours without edges,” IEEE Transactions on Image Processing, Vol. 10, No. 2, pp. 266-277, 2001.
[33]Li, C., Kao, C. Y., Gore, J. C., and Ding, Z., “Minimization of re-gion-scalable fitting energy for image segmentation,” IEEE Transactions on Image Processing, Vol. 17, No. 10, pp. 1940-1949, 2008.
[34]Li, C., Xu, C., Gui, C., and Fox, M. D., “Distance regularized level set evolution and its application to image segmentation,” IEEE Transactions on Image Processing, Vol. 19, No. 12, pp. 3243-3254, 2010.
[35]http://www.naturalhealthschool.com/bronchi_trachea.html
[36]http://www.studyblue.com/notes/note/n/ap-3/deck/4393365
[37]http://www.studyblue.com/notes/note/n/respiratory-system-/deck/6304082
[38]Herrera, P., Caldarone, C., Forte, V., Campisi P., Holtby H., Chait P., Chiu P., Cox P., Yoo S. J., Manson, D., and Kim, P. C. W., “The current state of congenital tracheal stenosis,” Pediatric Surgery International, Vol. 23, No. 11, pp. 1033-1044, 2007.
[39]Gonzalez, R. C., and Woods, R. E., “Digital Image Processing, 3rd edition,” Prentice-Hall, New York, 2008.
[40]Ioannis, P., and Venetsanopoulos, A.N., “Order statistics in digital image processing,” Proceedings of the IEEE, Vol. 80, No. 12, pp. 1893-1921, 1992.
[41]Kass, M., Witkin, A., and Terzopoulos, D., “Snakes: Active con-tour models,” International Journal of Computer Vision, Vol. 1, No. 4, pp. 321-331, 1988.
[42]Sussman, M., Smereka, P., and Osher, S., “A level set approach for computing solutions to incompressible two-phase flow,” Journal of Computational Physics, Vol. 114, No. 1, pp. 146-159, 1994.
[43]Adams, R., and Bischof, L., “Seeded region growing,” IEEE Transactions on Pattern Analysis and Machine Intelligence, Vol. 16, No. 6, pp. 641-647, 1994.
[44]Lorensen, W. E., and Cline, H. E., “Marching Cubes: a High Res-olution 3D Surface Construction Algorithm,” Computer Graphics (ACM), Vol. 21, No.4, pp. 163-169, 1987.
[45]繆紹綱等,數位影像處理活用MATLAB,全華圖書股份有限公司,(2010)。
[46]鄒錦聰等,MATLAB程式設計,全華科技圖書股份有限公司,(2003)。
[47]連國珍等,數位影像處理MATLAB,儒林圖書有限公司,(2009)。
[48]S. Carsten, U. Markus, and W. Christian, 機器視覺演算法與應用,新亞洲儀器股份有限公司,(2011)。
[49]鍾國亮,影像處理與電腦視覺(第四版),東華書局,(2008)。
[50]簡村誠,”口腔磁振影像舌頭構造之自動分割”,國立中央大學,電機工程研究所,碩士論文,(2009)。[51]范振添,“醫療影像傳輸及資料探索之系統開發”,中原大學,醫學工程學研究所,碩士論文,(2002)。