本研究應用熔射覆膜技術於鋼板接合面以提升滑移係數,增加摩阻型螺栓接合強度,並探討螺栓排列對接合強度之影響。採用八顆高強度螺栓之摩阻型接合進行滑移實驗,探討螺栓在不同矩陣排列下對滑移係數、螺栓預拉力、連接板應變值及摩阻力的影響。試體採用150
In this study, thermal sprayed coating was applied to the faying surface of steel plates in order to increase the slip coefficient and enhance the slip resistance of the slip-critical joint. Moreover, this study aims to explore the effect of bolt arrangement on slip resistance. Slip tests of slip-critical connection using eight high-strength bolts were carried out to explore the effects of different bolt arrangement on the slip coefficient, bolt pretension, stress on the splice plate, and slip resistance. Splice plates of the specimens were thermal sprayed coated with 150
摘要 i
ABSTRACT iii
誌謝 v
目錄 vi
表目錄 viii
符號表 xii
第一章 緒論 1
1.1 研究背景 1
1.2 研究目的 5
1.3 研究方法 5
1.4 論文構架 6
第二章 文獻回顧 7
2.1 前言 7
2.2 滑移實驗相關規定 7
2.3 單顆螺栓滑移實驗 9
2.4 多顆螺栓滑移實驗 10
第三章 八顆螺栓滑移實驗計畫 13
3.1 前言 13
3.2 試體參數規劃 13
3.3 實驗試體設計 14
3.4 滑移係數計算 16
3.5 熔射覆膜範圍及厚度量測 16
3.6 實驗設備與設置 18
3.6.1 螺栓預拉力量測 19
3.6.2 鋼板滑移量量測 21
3.6.3 鋼板應力量測 22
3.7 實驗程序 24
第四章 實驗結果與討論 26
4.1 試體行為 26
4.1.1 試體1×8系列 28
4.1.2 試體2×4系列 32
4.1.3 試體4×2系列 35
4.1.4 試體8×1系列 38
4.2 實驗結果比較 41
4.3 實驗結果討論 45
4.3.1 螺栓預拉力與載重之關係 45
4.3.2 螺栓預拉力與滑移量之關係 50
4.3.3 鋼板應變分佈 55
4.3.4 摩阻力分佈與連接板應變關係 65
第五章 結論與建議 75
5.1 結論 75
5.2 建議 76
參考文獻 78
American Association of State Highway and Transportation Officials (AASHTO). (2016). LRFD Bridge Design Specification. IL: American Association of State Highway and Transportation Officials, Inc.
ASTM E8/E8M (2011). Standard Test Methods for Tension Testing of Metallic Materials, American Society for Testing and Materials.
ASTM E111 (2017). Standard Test Methods for Young’s Modulus, Tangent of Modulus, and Chord Modulus, American Society for Testing and Materials.
American Institute of Steel Construction (AISC). (2016). Specification for Structural Steel Buildings. Chicago, IL: American Institute of Steel Construction, Inc.
Annan, C.D., Chiza, A., Fafard, M., Lévesque, É. (2014). Resistance of corrosion-resistant metalize faying surface used with slip-critical bolted connection. World Steel Bridge Symposium.
Hung, Y. H., Wang, R. H., Zou, J. H., Gan, Q. (2010). Finite element analysis and experimental study on high strength bolted friction grip connections in steel bridges. Journal of Constructional Steel Research, Vol. 66, 803-815.
Kojima, K., Saburi, K., Matsuo, S., Inoue, K. (2009). Slip coefficients and relaxation characteristics of high strength bolted joints with aluminum splayed splice plates. Architectural Institute of Japan, Vol. 49, 385-388.
Murakoshi, J., Sawada, M., Yamaguchi, T., Peng, X., Ootake, A. (2014). Slip resistance tests of friction-type high-strength multi bolted joints with coated contact surfaces by inorganic znc rich paint on thick plate. Journal of Japan Society of Civil Engineers, Ser. AI, Vol. 70, 94-104.
Peng, X., Yamaguchi, T., Takai, T., Murakoshi, J., Sawada, M. (2013). FEA study on the slip behavior of high strength multi bolted friction type joints with thick plates by structural dimensions. Journal of Japan Society of Civil Engineers, Ser. AI, Vol. 69, 452-466.
Research Council on Structural Connections (RCSC). (2014). Specification for structural joints using high-strength bolts. Chicago, IL: American Institute of Steel Construction, Inc.
They Society for Protective Coatings (SSPC). (2012). Coating application standard No. 2. SSPC-PA2. Pittsburgh, American.
中華民國鋼結構協會 (2012)。「鋼結構設計手冊(極限設計法)」。
內政部營建署 (2007)。「鋼構造建築物鋼結構施工規範」。
內政部營建署 (2010)。「鋼結構極限設計法規範及解說」。
陳哲生 (2005)。「鋼結構防蝕」,鋼結構會刊,第19期。
陳誠直、張誠、李思維 (2018)。「熔射覆膜技術應用於摩阻型螺栓接合」,第十屆海峽兩岸及香港鋼結構技術交流會論文集,第157-165頁。
漢泰科技 (2018)。「熔射覆膜產品型錄」。
潘吉齡、林新華、余志鵬、林政億 (2007)。「高性能鋼材應用於建築結構之研究」,內政部建築研究所委託研究報告。
蕭威典、劉武漢 (2008)。「熔射覆膜技術之應用與市場概況」,工業材料雜誌,第57期。
謝宗成 (2017)。「應用熔射覆膜技術於摩阻型螺栓接合之滑移係數探討」,國立交通大學土木工程學系碩士論文,陳誠直指導。
連結至畢業學校之論文網頁點我開啟連結
註: 此連結為研究生畢業學校所提供,不一定有電子全文可供下載,若連結有誤,請點選上方之〝勘誤回報〞功能,我們會盡快修正,謝謝!
QRCODE
 
 
 
 
 
                                                                                                                                                                                                                                                                                                                                                                                                               
第一頁 上一頁 下一頁 最後一頁 top