1.非製造業能源查核年報,財團法人台灣綠色生產基金會,2009。
2.EPA. 2007. “Report to Congress on Server and Data Center 1. Energy Efficiency.” Washington, D.C.: U.S. Environmental Protec¬tion Agency.
3.Vail Sorell, S. Escalante, JYang,"Comparison of Overhead Underfloor Air Delivery Systems in a Data Center Environment Using CFD Modeling," ASHRAE Transaction 111, 2005, pp.756-764.
4.C. Karki,"Airflow distribution through perforated tiles in raised-floor data centers," Building and Environment, 2006,pp.734-744.
5.V. Patankar, "Airflow and Cooling in a Data Center," Journal of Heat Transfer, Vol.132, 2010, pp. 1-17.
6.V. Sorell, V. Gandhi, Y Abougabal,A. Watve, K. Khankari," An Analysis of the Effects of Ceiling Height on Air Distribution on Data Centers, ASHRAE Transaction 112, 2006, pp.623-631.
7.K. Herrlin, Rack Cooling Effectiveness in Data Centers and Telecom Central Offices: The Rack Cooling Index(RCI), ASHRAE Transaction111,2005, pp.756-764.
8.李魁鵬,電信網路機房-節能應用手冊,財團法人台灣綠色生產基金會,2010,第38-63頁。
9.R. Schmidt, D. Beaty, M. Lyengar,S. Shrivastava, Thermal Profile of a High-Density Data Center:Hot Spot Heat Fluxes of 512 W/ft^2,ASHRAE Transaction 111, 2005, pp.765-777.。
10.C. Mike Scofield, Thomas S. Weaver., "Using Wet-Bulb Economizes Data Center Cooling," ASHRAE Journal, vol.50,2008, pp. 62-67.
11.Dunnavant, "Indirect Air-Side Economizer Cycle Data Center Heat Rejecting," ASHRAE Journal,vol.53 ,2011, pp. 44-48.
12.Zac Potts MEng, Free Cooling Technologies in Data Centre Applications, http://www.datacentre.me/downloads/Documents/Sudlows%20-%20FreeCooling_Draft_ZP3.pdf
13.Anubhav Kumar,"USE OF AIR SIDE ECONOMIZER FOR DATA CENTER THERMAL MANAGEMENT," Master ,Georgia Institute of Technology,2008.
14.Arman Shehabi , Srirupa Ganguly , Lara A. Gundel , Arpad Horvath , Thomas W. Kirchstetter ,Melissa M. Lunden , William Tschudi , Ashok J. Gadgil , William W. Nazaroff," Can combining economizers with improved filtration save energy and protect equipment in data center?," Building and Environment, vol.45, 2010, pp. 718-726.
15.Arman Shehabi, Arpad Horvath, William Tschudi, Ashok J. Gadgil, William W Nazaroff, "Particle concentrations in data centers," Atmospheric Environment, , vol.42, 2008, pp. 5978-5990.
16.Arman Shehabi, Eric Masanet, Hillary Price, Arpad Horvath, William W Nazaroff, "Data center design and location: Consequences for electricity use and greenhouse-gas emissions" Building and Environment, vol.46, 2011, pp.990-998.
17.A.S. Kaiser, M. Lucas, A. Viedma, B. Zamora, "Numerical model of evaporative cooling processes in a new type of cooling tower" International Journal of Heat and Mass Transfer , vol.48, 2005, pp.986-999.
18.LBNL, Data center website of Lawrence Berkeley National Laboratory, http://datacenter.lbl.gov/,2005.
19.ASHRAE Technical Committee TC 9.9.
20.Jon Hass, The Green Grid Proxy Proposals for Measuring Data Center Productivity,http://www.thegreengrid.org/~/media/WhitePapers/White%20Paper%2017%20-%20Proxies%20Proposals%20for%20Measuring%20Data%20Center%20Efficiencyv2.pdf?lang=en.
21.FLUENT User’s Guide, Version 6.3, FLUENT Inc, USA, 2006.
22.Jay park, OPEN Compute Project Data Center V1.0, http://www.mvdirona.com/jrh/TalksAndPapers/Open_Compute_Project_Data_Center_v1.0.pdf.
23.思沛雅噴霧器材有限公司,MA系列超音波物化噴嘴型錄介紹,http://www.sprayernozzle.com.tw/p3-1-1-1.aspPage=1&Sn2=46&Sn3=280.
24.劉福田,劉希平,微粒導論,國立編譯館出版,2001,第337-350頁。
25.CompuSpace, PLENAFORM,http://www.plenaform.com/PlenaAxonometric4.gif.
26.東菀駿科空調製造有限公司,http://www.techfree.com.cn/images/products/big5/AHU/TFCC%20Technical%20Data.jpg.
27.吳旭聖,江旭政,"資訊機房PUE值量測與發展" 冷凍空調&能源科技,八月,2011,第17-24頁。
28.江旭政,"雲端運算和數據機房冷卻技術發展",冷凍空調&能源科技,十月,2010,第21-26頁。
29.張銘陽,網路資料中心空調節能設計之模擬分析,碩士論文,國立臺北科技大學能源與冷凍空調工程系,台北,2009。30.王祥勇,資料中心耗能監測與模擬分析,碩士論文,國立臺北科技大學能源與冷凍空調工程系,台北,2009。
31.2005年6月9日發表Cost Model for Planning, Development and Operation of a Data Center)加州大學伯克利分校,CA94720-1742批准對外發布(權所有2005年惠普開發公司) 。
32.李智軒,數據中心蒸發冷卻之數值模擬Numerical Simulation of Evaporative Cooling in Data Centers碩士論文,國立臺北科技大學能源與冷凍空調工程系,台北,2012。