[1] 台灣能源指標,台灣能源統計年報,經濟部能源局,2017年5月3日取得 http://emis.erl.itri.org.tw/_upload/_admin/ecpaper/7/file/%e7%ac%ac%e5%85%ad%e7%ab%a0.pdf
[2] 蔡尤溪、羅欽煌,「電力照明及空調節能」,辦公大樓節約能源手冊,2009,第1頁
[3] 劉中哲,廣域高效率離心式冰水機系統技術,能源與冷凍空調雜誌,2009
[4] 詹朝棋,離心式冷媒壓縮機之非設計點工況性能提升研究,碩士論文,國立勤益科技大學冷凍空調與能源所,台中,2011[5] 陳森煌,以現場實用測量結果作冰水主機部分負載之性能分析,碩士論文,國立臺北科技大學能源與冷凍空調工程所,台北,2001[6] 游本良,冷卻水溫度與冰水溫度對離心式冰水主機性能影響之實驗分析,碩士論文,國立中央大學,桃園,2006[7] 李奕軒,冰水主機與冷卻水塔控制策略之耗能分析,碩士論文,國立臺北科技大學能源與冷凍空調工程所,台北,2008[8] 陳緯中,變頻離心機冰水主機於台灣氣候條件下運轉效益分析,碩士論文,國立勤益科技大學冷凍空調與能源所,台中,2010[9] 黃慶德,冷媒膨脹閥特性探討,碩士論文,國立交通大學機械工程所,新竹,1996[10] 黃鴻河,R-134a應用於雙蒸發器冷凍系統之效能研究,碩士論文,國立臺北科技大學能源與冷凍空調工程所,台北,2005[11] 鄭國豐,壓縮機活塞缸之流場,碩士論文,國立雲林科技大學機械工程所,雲林,2007[12] A.B. Little and S. Garimella, “Shadowgraph visualization of condensing R134a flow through ejectors”, International Journal of Refrigeration 68 (2016) 118–129
[13] G.W. Mann, G.R. Madamadakala, S.J. Eckels, “Heat transfer characteristics of R-134a in a converging-Diverging nozzle”, International Journal of Heat and Fluid Flow 000 (2016) 1–10
[14] J. Yan, C. Lin, W. Cai, H. Chen, H. Wang, “Experimental study on key geometric parameters of an R134A ejector cooling system”, International Journal of Refrigeration 67 (2016) 102–108
[15]W. Chen, C. Shi, S. Zhang, H. Chen, D. Chong, J. Yan, “Theoretical analysis of ejector refrigeration system performance under overall modes”, Applied Energy (2016)
[16]Z. Ding, L. Wang, H. Zhao, H. Zhang, C. Wang, “Numerical study and design of a two-stage ejector for subzero Refrigeration” Applied Thermal Engineering 108 (2016) 436-448
[17] J. Liu, L. Wang, L. Jia, X. Wang, “The influence of the area ratio on ejector efficiencies in the MED-TVC desalination system”, Desalination 413 (2017) 168-175
[18]H. Wang, W. Cai, Y. Wang, J. Yan, L. Wang, “Experimental study of the behavior of a hybrid ejector-based air-conditioning system with R134a”, Energy Conversion and Management 112 (2016) 31-40
[19] W. Hou, L. Wang, J. Yan, X. Li, L. Wang, “Simulation on the performance of ejector in a parallel hybrid ejector-based refrigerator-freezer cooling cycle”, Energy Conversion and Management 143 (2017) 440-447
[20]K. Huang, X. Guo, P. Zhang, “Influence of Structural Parameters of Two-Throat Nozzle Ejector on Performance of Two-phase Flow Ejector Refrigeration System”, Energy Procedia 105 (2017) 5091-5097
[21]H. Zhao, K. Zhang, L. Wang, J. Han, “Thermodynamic investigation of a booster-assisted ejector refrigeration system”, Applied Thermal Engineering 104 (2016) 274-281
[22]M. Mojaddam, A. Hajilouy-Benisi, “Experimental and numerical flow field investigation through two types of radial flow compressor volutes” Experimental Thermal and Fluid Science 78 (2016) 137-146
[23]X. Zhu, G. Li, W. Jiang, L. Fu, “Experimental and numerical investigation on application of half vane diffusers for centrifugal pump”, International Communications in Heat and Mass Transfer 79 (2016) 114–127
[24]財團法人台灣綠色生產力基金會,「2016年非生產性質行業能源查核年報」,2017年5月5日取得,http://www.ecct.org.tw/knowledge/knowledge/2016年非生產性質行業能源查核年報.pdf
[25] CARRIER,19XR Hermetic Centrifugal Liquid Chillers with PIC-III Controls, Start-Up Operation and instructions,Carrier Corporation,2010 Pages 7, Pages 39
[26] Carrier,冰水主機教育訓練資料,開利冷氣,台北,2015
[27] M.J. Moran, H.N. Shapiro, B.R. Munson, D.P. DeWitt, “Control Volume Analysis Using Energy”, Introduction to Thermal Systems Engineering: Thermodynamics, Fluid Mechanics, and Heat Transfer, John Wiley & Sons, Inc., p.104, 2003
[28] ARI, Standard for Water Chilling Package Using the Vapor Compression Cycle,“Air-Conditioning and Refrigeration Institute” Institute, Standard 550/590, Pages 3-12 ,2003
[29] 中央氣象局觀測資料查詢系統,「觀測資料查詢系統」,2017年5月3日取得,http://eservice.cwb.gov.tw/HistoryDataQuery/index.jsp
[30] 鼎宏儀器公司,流量計規格,2017年5月3日取得,http://www.sunnyinstrument.com/product/html/?62.html