1. Clark Jr L. C., Lyons C., “Electrode systems for continuous monitoring in cardiovascular surgery”, Annals of the New York Academy of Sciences, Vol. 102, pp. 29-45 (1962).
2. J. Castillo., Gáspár. S., S. Leth., M. Niculescu., A. Mortari., I. Bontidean., V. Soukharev., S.A. Dorneanu., A.D. Ryabov., E. Csöregi., “Biosensors for life quality: Design, development and applications”, Sensors and Actuators B: Chemical, Vol. 102, No. 2, pp.179-194 (2004).
3. Walter H Brattain, Bardeen John,“Three-electrode circuit element utilizing semiconductive materials”, Bell Telphone Lab Inc., U.S. Pat.,2524035 (1950).
4. N.C. Danbolt, “Glutamate uptake”, Progress in Neurobiology, Vol. 65, pp.1-105 (2001).
5. R.J. Weinberg, “Glutamate: an excitatory neurotransmitter in the mammalian CNS”, Brain Research Bulletin, Vol. 50, pp. 353-354 (1999).
6. M. Fillenz, “Physiological release of excitatory amino acids”, Behav. Brain Res., Vol. 71, pp. 51-67 (1995).
7. T.P. Obrenovitch, J. Urenjak ,“ALTERED GLUTAMATERGIC TRANSMISSION IN NEUROLOGICAL DISORDERS: FROM HIGH EXTRACELLULAR GLUTAMATE TO EXCESSIVE SYNAPTIC EFFICACY”, Progress in Neurobiology, Vol. 51, pp. 39-87 (1997).
8. P.J. Conn, J.P. Pin, “Pharmacology and functions of metabotropic glutamate receptors”, Annu Rev Pharmacol Toxicol, Vol. 37, pp. 205-237 (1997).
9. J.W. Olney, N.B. Farber, “Glutamate receptor dysfunction and schizophrenia”, Arch. Gen. Psychiatry, Vol. 52, pp. 998-1007 (1995).
10. J. Smythies, “Redox mechanisms at the glutamate synapse and their significance: a review”, Eur J Pharmacol., Vol. 370, pp. 1-7 (1999).
11. Sitges et al., “Effects of carbamazepine, phenytoin, lamotrigine, oxcarbazepine, to piramate and vinpocetine on Na+ channel-mediated release of [H] glutamate in hippocampal nerve endings”, Neuropharmacology, Vol. 52, pp. 598-605 (2007).
12. G. Szénási, J.L.G. Hársing, “Pharmacology and prospective therapeutic usefulness of negative allosteric modulators of AMPA receptors”, Drug Discovery Today: Therapeutic Strategies, Vol. 521, pp. 69-76 (2004).
13. Ghobadi S, Csöregi E, Marko-Varga G, “Bienzyme carbon paste electrodes for L-glutamate determination”, Current Separations, Vol. 14, pp. 94-102 (1996).
14. E. Valero, F. Garcia-Carmona, “A Continuous Spectrophotometric Method Based on Enzymatic Cycling for Determining L-Glutamate”, ANALYTICAL BIOCHEMISTRY, Vol. 259, pp. 265-271 (1998).
15. J. Chapman, M. Zhou, “Microplate-based fluorometric methods for the enzymatic determination of L-glutamate: application in measuring l-glutamate in food samples”, Analytica Chimica Acta, Vol. 402, pp. 47-52 (1999).
16. T.P. Piepponen, A. Skujins, “Rapid and sensitive step gradient assays of glutamate, glycine, taurine and g-aminobutyric acid by high-performance liquid chromatography–fluorescence detection with o-phthalaldehyde–mercaptoethanol derivatization with an emphasis on microdialysis”, Journal of Chromatography B, Vol. 757, pp. 277-283 (2001).
17. A. Tivesten, A. Lundqvist, S. Folestad, “Selective chiral determination of aspartic and glutamic acid in biological samples by capillary electrophoresis”, Chromatographia, Vol. 44, pp. 623-633 (1997).
18. Iniouchine, M.Y., et al., “Blockers of monoamine transporters influence high dopamine concentration uptake in rat brain slices”, Doklady Biological Sciences, Vol. 419, No. 1, pp. 80-82 (2008).
19. Wei WJ, Song YL, Shi WT et al., “A high sensitivity MEA probe for measuring real time rat brain glucose flux”, Biosensors and Bioelectronics, Vol. 55, pp. 66-71(2014).
20. M.R. Ryan, J.P. Lowry, R.D. O‘Neill, “Biosensor for neurotransmitter l-glutamic acid designed for efficient use of l-glutamate oxidase and effective rejection of interference, Analyst, Vol. 122, pp. 1419-1424 (1997).
21. Å. Hallström, A. Carlsson, L. Hillered, U. Uncerstedt, “Simultaneous determination of lactate, pyruvate, and ascorbate in microdialysis samples from rat brain, blood, fat, and muscle using high-performance liquid chromatography”, Journal of Pharmacological Methods, Vol. 22, No. 2, pp.113-124 (1989).
22. C. Debiemme-Chouvy, “A Very Thin Overoxidized Polypyrrole Membrane as Coating for Fast Time Response and Selective H2o2 Amperometric Sensor”, Biosensors & Bioelectronics, Vol. 25, pp. 2454-57 (2010).
23. S. T. Pan, and M. A. Arnold, “Selectivity Enhancement for Glutamate with a Nafion/Glutamate Oxidase Biosensor”, Talanta, Vol. 43, pp. 1157-62 (1996).
24. R. D. O'Neill, S. C. Chang, J. P. Lowry et al, “Comparisons of Platinum, Gold, Palladium and Glassy Carbon as Electrode Materials in the Design of Biosensors for Glutamate”, Biosensors & Bioelectronics, Vol. 19, pp. 1521-28 (2004).
25. M. Ammam, and J. Fransaer, “Hghly Sensitive and Selective Glutamate Microbiosensor Based on Cast Polyurethane/Ac-Electrophoresis Deposited M ultiwalled Carbon Nanotubes and Then Glutamate Oxidase/Electrosynthesized Polypyrrole/Pt Electrode”, Biosensors & Bioelectronics, Vol. 25, pp. 1597-602 (2010).
26. S. Govindarajan, C. J. McNeil, J. P. Lowry, C. P. McMahon, R. D. O'Neill ,“Highly selective and stable microdisc biosensors for l-glutamate monitoring”, Sensors and Actuators B: Chemical, Vol. 178, pp. 606-614 (2013).
27. M. Zhang, C. Mullens, W. Gorski, “Amperometric glutamate biosensor based on chitosan enzyme film”, Electrochimica Acta, Vol. 51, No. 21, pp. 4528-4532(2006).
28. O. V. Soldatkina, O. O. Soldatkin, B. Ozansoy Kasap et al., “A Novel Amperometric Glutamate Biosensor Based on Glutamate Oxidase Adsorbed on Silicalite”, Nanoscale Research Letters, Vol. 12, No. 1, pp. 2026-8 (2017).
29. M. Bäcker, L. Delle, A. Poghossian, M.Biselli, W. Zang et al., “Electrochemical sensor array for bioprocess monitoring”, Electrochimica Acta, Vol. 56, No. 26, pp. 9673-9678 (2011).
30. V. M.Tolosa, K. M. Wassum, N. T. Maidment et al., “Electrochemically deposited iridium oxide reference electrode integrated with an electroenzymatic glutamate sensor on a multi-electrode arraymicroprobe”, Biosensors and Bioelectronics, Vol. 42, pp. 256-260 (2013).
31. O. Frey, T. Holtzman, R. M. McNamara et al., “Enzyme-based choline and l-glutamate biosensor electrodes on silicon microprobe arrays”, Biosensors and Bioelectronics, Vol. 26, No. 2, pp. 477-484 (2010).
32. Wenjing Wei, Yilin Song, Li Wang et al., “An implantable microelectrode array for simultaneous L-glutamate and electrophysiological recordings in vivo”, Microsystems & Nanoengineering,15002 (2015).
33. Eric Walker, Jianjun Wang, Naser Hamdi et al., “Selective detection of extracellular glutamate in brain tissue using microelectrode arrays coated with over-oxidized polypyrrole”, The Analyst, Vol. 132, pp. 1107-1111 (2007).
34. Michael W. Varney, Dean M. Aslam, Abed Janoudi et al., “Polycrystalline-Diamond MEMS Biosensors Including Neural Microelectrode-Arrays”, Biosensors (Basel), Vol. 1, No. 3, pp. 118-133 (2011).
35. Matthew D.Johnson, Robert K.Franklin, Matthew D.Gibson et al., “Implantable microelectrode arrays for simultaneous electrophysiological and neurochemical recordings”, Journal of Neuroscience Methods, Vol. 174, No. 1, pp. 62-70 (2008).
36. KarlSchügerl, “Progress in monitoring, modeling and control of bioprocesses during the last 20 years”, Journal of Biotechnology, Vol. 85, No. 2, pp. 149-173 (2001).
37. Huicheng Yu, Zhenzhen Ma, Zhaoyang Wu, “Immobilization of Ni–Pd/core–shell nanoparticles through thermal polymerization of acrylamide on glassy carbon electrode for highly stable and sensitive glutamate detection”, Analytica Chimica Acta, Vol. 896, pp. 137-142 (2015).
38. Qi Zeng, Kai Xia, Bin Sun et al., “Electrodeposited Iridium Oxide on Platinum Nanocones for Improving Neural Stimulation Microelectrodes”, Electrochimica Acta, Vol. 237, pp. 152-159 (2017).
39. D. Carelli, D. Centonze, A. De Giglio, M. Quinto, and P. G. Zambonin, “An Interference-Free First Generation Alcohol Biosensor Based on a Gold Electrode Modified by an Overoxidised Non-Conducting Polypyrrole Film”, Analytica Chimica Acta, Vol. 565, pp. 27-35 (2006).
40. M. Q. Liu, J. H. Jiang, Y. L. Feng et al., “Glucose Biosensor Based on Immobilization of Glucose Oxidase in Electrochemically Polymerized Polytyramine Film and Overoxidised Polypyrrole Film on Platinized Carbon Paste Electrode”, Chinese Journal of Analytical Chemistry, Vol. 35 , pp. 1435-38 (2007).
41. N. Wahono, S. Qin, P. Oomen et al., “Evaluation of Permselective Membranes for Optimization of Intracerebral Amperometric Glutamate Biosensors”, Biosensors & Bioelectronics, Vol. 33, pp. 260-66 (2012).
42. Xiao, H. 著,羅正忠、張鼎張 譯,台灣培生教育出版:學銘圖書發行,台北,半導體製程技術概論(Introduction to Semiconductor Manufacturing Technology), (2002)。
43. 張鴻彥,「利用微電極陣列感測探針探討痛覺刺激與穀氨酸於脊隨丘腦逕之神經傳導的關聯」,碩士論文,國立台灣科技大學,台北(2015)。44. 盧偉凡,「微機械加工技術製備微電極陣列探針與測量分析物絕對濃度的方法」,碩士論文,國立台灣科技大學,台北(2014)。45. 余政霖,「應用於生物感測器之植入型微電極陣列探針製備與微影光罩改良」,碩士論文,國立台灣科技大學,台北(2014)。46. 詹文進,「選擇性酵素固定法製備電流式微電極陣列穀氨酸感測器」,碩士論文,國立台灣科技大學,台北(2013)。