AbstractThe purpose of this thesis is to investigate the optimum parameters ofwind-proof exhauster. The experimental fuels of the water heater areas Propane and Butane. The studying parameters include size of outlet,height of baffle plate and angle of oblique plate. The excess air ratio, CO ratio and combustion efficiency are measured to determine thewin-proof performance. The win-proof exhauster of the present researchis a type of well win-proof performance and simple type. The Chinese National Standard 3661, 3662, 13602, 13603, and 10671 are selected asthe guidelines in present experimental study. The results shows thatsize of outlet must be more than 100mm to satisfy the CNS requirementfor CO ratio. And there is the largest out flow occur at the distanceof 37.14mm between the outlet and the baffle plate when the obliqueplate angle degree is 30. Therefor to consult the fine combustionefficiency and to satisfy the CNS requirement for CO ratio, we advicethe angle degree of the oblique plate is 45.Key words:wind-proof exhauster, height of baffle plate, angle ofoblique plate.
|