[1] 李景亮、梁英文, 1997,6月, ”結構耐震設計”,文笙書局.
[2] ACI Committee 440, 1995,“Abstract of : State-the —Art-Report on Fiber Reinforced Plastic (FRP) for Concrete Structures”, ACI Structural Journal,V92,No.5.
[3] 彭添富、李有豐、施邦築、朱國棟、邱佑宗、鄭育祥,“碳纖維強化高分子複合材料(CFRP)應用於簡支鋼筋混凝土樑之補強最佳化設計與驗證”,結構工程第十二卷第四期六月,pp.87-99,1996.[4] 李秉乾、張國鎮、張順賓,“圓形橋柱碳纖維耐震補強之研究”,國家地震工程研究中心,報告編號: NCREE-99-037, 1999.
[5] 李秉乾、李宗澤、吳岱祐、廖為忠、李慶昌,“複合材料補強鋼筋混凝土樑之研究1999年尖端材料及製造科技學術研究會”,中華民國尖端材料科技協會.
[6] 黃兆龍、湛淵源、郭金祥、劉益雄,“地震後結構修補材料之耐久性探討”,1999年期中研究成果研究會論文集,pp.140-181.
[7] ACI Committee 318, “Building Code Requirements for Structural Concrete (ACI 318-95) and Commentary (ACI 318R-95),” American Concrete Institute, Farmington Hills,1995,369 pp.
[8] Architectural Institute of Japan, “Design Guidelines for
Earthquake Resistant Reinforced Concrete Buildings Based on Ultimate Strength Concept and Commentary,”(in Japanese), 340pp.,October,1990.
[9] Concrete Structures Standard (NZS 310:1995), “Part1 the Design of Concrete”, Standards Association of New Zealand, Wellington, 256pp.
[10] Concrete Structures Standard (NZS 310:1995), “Part2 Commentary on The Design of Concrete Structures”, Standards Association of New Zealand,Wellington,264pp.
[11] Hanson, N.W., and H. W. Connor, “Seismic Resistance of Reinforced Concrete Beam-Column Joint”, Journal of Structural Division, Proceedings of the ASCE, Vo1.93, No.ST5, pp.533-560. October ,1967.
[12] Kanada,K.,G. Kondon,, S. Fujii, and S. Morita, “Relation Between Beam Bar Anchorage and Shear Resistance at Exterior Beam-Column Joints.” Transactions of the Japan Concrete Institute, Vo1.6,pp.433-440,1984.
[13] Shyu-Jiann Hwang and Hung-Jen Lee, “Analytical Model for Predicting Shear Strengths of Interior Reinforced Concrete Beam-Column Joints for Seismic Resistance”, ACI Structural Journal, January-February,V.97,No.1,2000.
[14] Kent,D.C.and Park,R..,“Flexural members with confined concrete”, Journal of the Structural Division, ASCE,Vo1.97, pp.1969-1990. July, 1971.
[15] Muguruma,H.,W atanabe,S.,Tanaka.S.,Sakurai.K.,and Nakaruma,E. 1978, “A Study on the Improvement of Bending Ultimate Strain of Concrete.”, J. Struct. Engrg., Tokyo, Japan, 24, pp. 109-116.
[16] Muguruma,H., Watanabe,S.,Tanaka.S.,Sakurai.K.,and Nakaruma,E. 1978, “ A Stress-Strain Model of Confined Concrete”., Proc., JCA Cement and Concrete, Vo1.34,Japan Cement Assn.,Tokyo, Japan.pp.429-432.
[17] Mander, J.B.,M.J.N. Priestley, and R.Park,R.1988, “Observed
Stress-Strain behavior of confined concrete,” Journal of the Structural Division,ASCE,97(7),pp.1969-1990.
[18] Mander, J.B.,M.J.N. Priestley, and R.Park, “Theoretical stress-strain Mode for Confined Concrete”, Journal of the Structural Division,ASCE,Vo1.114,No.8,pp.1804-1826. August, 1988.
[19] Mander, J.B., M.J.N .Priestley, and R.Park,1984. February,
“Seismic Design of Bridge Piers”, Department of Civil Engineering, University of Canterbury, Report 84-2,pp.483.
[20] Philip A. Ritchie,David A.Thomas, Le-Wu Lu, and Guy M. Connelly, “External Reinforcement of Concrete Beams Using Fiber Reinforced Plastics”, ACI Structural Journal, Title No.88-S52, pp.490-500. July-Augsut,1991.
[21] Grace, N.F. Sayed G.A., Soliman A.K. and Saleh K.R., “Strengthening Reinforced Concrete Beam Using Fiber Reinforced Polymer (FRP) Laminates”, ACI Structural Journal, Title No.96.Septenber-October 1999.
[22] 蕭興臺、閻嘉義、簡顯光、詹清淵., “RC 樑側貼鋼板補強工法之研究”,第四屆結構工程研究會,PP.1951-1956,1998.
[23] R.Ma and Yan Xiao, “ Seismic Retrofit and Repair Circular Bridge Columns with Advanced Composite Materials”, M.EERI, Earthquake Spectra, Volume 15, No.4,Novermber 1999.
[24] 日本財團法人,鐵路總合技術研究所,平成八年., “碳纖維複合材於鐵道高架橋柱之耐震補強工法設計及施工指針”.
[25] 王仲宇, “含裂縫及損傷之鋼筋混凝土結構之貼片補強分析( )”,國科會報告,NSC-84-2621-P-008-007-B.8月1995.
[26] 王仲宇.1996,8月“含裂縫及損傷之鋼筋混凝土結構之貼片補強分析( )-貼片補強工法應力分析和對策”,國科會報告,NSC-85-2621-P-008-004.
[27] Malek,A.M.and H.Saadatmanesh,1998, “Design Equations and Guidelines for Reinforced Concrete Beams Strengthened with FRP Plates,” in Fiber Composites in Infrastructure (Proceedings of the Second International Conference on Composites in Infrastructure, Tucson Arizona, USA, 5-7 Jan. 1998), Edited by H. Saadatmanesh and M.R.Ehsani, Vo1.I,pp603-916.
[28] Bjorn Taljsten, “Strengthening of Beams by Plate Bonding”, Journal of Materials in Civil Engineering,pp206-212. November,1997.
[29] ACI Committee 318 , “Building Code Requirement for Reinforced Concrete and Commentary (ACI 318-95/ACI 318R-95),” American Concrete Institute,Detroit,1995.
[30] Caltrans, “Memo to Designers Change Letter”, California Department of Transportation, Sacramento,Calif.,Mar.1995.
[31] Sheikh, Shamim, A., Shah, Dharmendra V. and Khaury, Shafik S., “Confinement of High-Strength Concrete Columns”, ACI Journal, Vol,91,No.1,January-February,1994,pp.100-111.
[32] Seible, Frieder, and Priestly, M.J.Nigel, Gilbert A. Hegemier, and Donato Innamorato, “Seismic Retrofit of Column with Continuous Carbon Fiber Jack.” Journal of Composites for Construction,pp.52-62. 1997.May.
[33] Caltrans, “Bridge Design Specification”, June 1986.
[34] M.J.N Priestley, F.Seible,and G.M. Calvi, “ Seimic Design and
Retrofit of Bridges”, John Wiley and Sons,Inc.,New York,1996.
[35] F. Seible, “Seismic Bridge Damage and Advanced Composite Retrofit of Bridge Columns”, Technical Seminar on Advanced Technologies for Bridge Infrastructure Renewal, N.T.U.,May 21to23,1997.
[36] Priestley, M.JN. and Park , R., “Strength and Ductility of Concrete Bridge Columns under Seismic Loading”, ACI Structural Journal,84(1),pp.61-75,1987.