|
1.Keith J. Dreyer, PACS a guide to the digital revolution. Springer, 2002 124-60. 2.H.K. Huang, PACS basic principles and applications. Willey-Liss & Sons 1999, 15-323. 3.Stewart C. Bushong, Radiologic science for technologists. Elsevier MOSBY 2004, 15-315. 4.Richard R. Carlton, Principles of radiographic imaging. DELMAR 1999, 614-46. 5.Hakan Geije, Karl-Wilhelm Beckman, Torbjorn Andersson et al., Image quality VS radiation dose for a flat-panel amorphous silicon detector: a phantom study, Eur. Radiol. 2001, 11:1704-1709. 6.Marika Ganten, Boris Radeleff, Annette Kampschulte et al., Comparing Image Quality of Flat-Panel Chest Radiography with Storage Phosphor Radiography and Film-Screen Radiography, AJR 2003, 181: 171-176. 7.Martin Uffmann, Cornelia Schaefer-Prokop, Ulrich Neitzel et al., Skeletal Application for Flat-panel versus Storage-Phosphor Radiography: Effect of Exposure on Detection of Low-contrast Details, Radiology 2004, 231:506-514. 8.W.P. Hosch, C. Fink, B. Radeleff et al., Radiation dose reduction in chest radiography using a flat-panel amorphous Silicon detector. Clinical Radiology 2002, 57:902:907. 9.Spahn M, Strotzer M, Volk M et al., Digital Radiography with a Large-Area, Amorphous-silicon, Flat-Panel X-ray Detector System, Invest Radiol 2000, 35:260-266. 10.Mark F. McEntee, Patrick C. Brennan, Geraldine O. Connor, The effect of X-ray tube potential on the image quality of PA chest radiographs when using digital image acquisition devices, Radiography 2004, 10: 287-292. 11.J. Freudenberger, E. Hell, W. Knupfer. Perspectives of Medical x-ray Imaging, Nuclear Instruments & methods in Physics Research A 2001, 466: 99-104. 12.Hee-Joung Kim, Jin-O Hong, Kyu-Ho Lee et al., Phantom and Animal Imaging Studies Using PLS synchrotron X-rays, IEEE Transactions on Nuclear Science 2001, 48(3): 837-842. 13.James T. DobbinsⅢ, Ehsan Samei, Harrell G. Chotas et al., Chest radiology: Optimization of X-ray Spectrum for Cesium Iodide-Amorphous Silicon Flat-Panel Detector, Radiology 2003, 226:221-230. 14.DDA, NOBUHIRORT, NAKATA HATIME, Optimal Beam Quality for Chest Computed Radiography, Invest. Radiol 1996, 31(3): 126-131. 15.Sheldon Wieder, Paul L. Adams, Improved Routine Chest Radiography with a Trough Filter, AJR 1981, 137:695-698. 16.Harrell G. Chotas, Carey E. Floyd, James T. DobbinsⅢ et al., Digital Chest Radiography with Photostimulable Storage Phosphors: Signal-to-Noise Ratio as a Function of Kilovoltage with Matched Exposure Risk, Radiology 1993, 186: 395-398. 17.J. H. Launders, A.R. Cowen, R. F. Bury et al., Towards Image Quality, Beam Energy and Effective Dose Optimisation in Digital Thoracic Radiography, Eur. Radiol. 2001, 11: 870-875. 18.Kees Koedooder, Henk W Venema, Filter materials for Dose Reduction in Screen-Film Radiography, Phys.Med. Biol. 1996, 31(6): 585-600. 19.M. Sandborg, C. A. Carlsson, G. Alm Carlsson, Shaping X-ray Spectra with filters in X-ray diagnostics, Medical & Biological engineering & computing, 1994, 32: 384-390. 20.Michael Strotzer, Markus Volk, Rudiger Frund et al., Routine Chest Radiography Using a Flat-panel Detector: Image Quality at Standard detector Dose and 33% Dose Reduction, AJR 2002, 178: January, 169-171. 21.Michael Strotzer, Josef Gmeinwieser, Markus Volk et al., Clinical Application of a Flat-Panel X-ray Detector Based on Amorphous Silicon Technology: Image Quality and Potential for Radiation Dose Reduction in Skeletal Radiography, AJR 1998, 171: 23-27. 22.Michael Strotzer, Markus Volk, Maximilian Reiser et al., Chest radiography with a large-area detector based on cesium-iodide/amorphous-silicon technology, Journal of thoracic imaging 2000, 15(3):157-161. 23.Marth Uffmann, Ulrich Neitzel, Mathias Prokop et al., Flat-panel-detector chest Radiography: effect of tube voltage on image quality, Radiology 2005, 235:642-650. 24.Siegfried Peer, Ulrich Neitzel, SalvatoreM. Giacomuzzi et al., Comparison of Low-Contrast Detail Perception on Storage Phosphor Radiographs and Digital Flat Panel Detector Images, IEEE 2001, 20(3): 239-242. 25.Jan Persliden, K. W. Beckman, H. Geijer et al., Dose-Image Optimisation in Digital Radiology with a Direct Digital Detector: an example Applied to Pelvic Examinations, Eur Radiol. 2002, 12:1584-1588. 26.Karl Ludwing, Horst Lenzen, Karl-friedrich Kamm et al., Performance of a Flat-panel Detector in Detecting Artificial Bone Lesions: Comparison with Conventional Screen-Film and Storage- Phosphor Radiography, Radiology 2002, 222:453-459. 27.Christian Fink , Peter J. Hallscheidt, Gerd Noeldge et al., Clinical Comparative Study with a Large-Area Amorphous Silicon Flat-Panel Detector: Image Quality and Visibility of Anatomic Structures on Chest Radiography, AJR 2002, 178: February, 481-486. 28.M. Volk, M. Strotzer, N. Holzknecht et al., Digital Radiography of the Skeleton Using a large-Area Detector Based on Amorphous Silicon Technology: Image Quality and Potential for Dose Reduction in Comparison with Screen-Film Radiography, Clinical Radiology 2000, 55: 615-621. 29.Terue Okamura, Saori Tanaka, Koichi Koyama et al., Clinical Evaluation of Digital Radiography Based on a Large-Area Cesium Iodide-amorphous silicon Flat-panel Detector compared with Screen-Film Radiography for Skeletal System and abdomen, Eur Radiol 2002 12: 1741-174. 30.P Baldelli, A Taibi, A Tuffanelli et al., Quasi-Monochromatic X-ray for Diagnosis Radiology, Phys. Med. Biol. 2003 48: 3653-3655. 31.蔡榮鍠 編譯 翁寶山 校閱, 最新放射物理學, 第四版, 新竹黎明書店, 662, 1984. 32.Quality Criteria development of the European Commission, European guidelines on quality criteria for diagnostic radiographic images, European commission, 1996 EUR 16260EN. 33.D J Gallacher, A Mackenzie, S Batchelor et al., Use of a Quality Index in Threshold Contrast Detail Detection Measurement in Television Fluoroscopy, BJR 2003, 76:464-472. 34.Hakan Geijer, Karl-Wilhelm Beckman, Torbjorn Andersson et l., image Quality vs radiation dose for a flat-panl amorphous silicon detector: a phantom study, Eur. Radiol. 2001, 11:1704-1709. 35.Gwyneth C. Weatherburn, J G Davies, comparison of film, hard copy computed radiography(CR) and soft copy picture archiving and communication (PACS) system using a contrast detail test object, BJR 1999, 72:856-863. 36.CNMC Company, Solid Water™ phantom material. 37.http://www.endlessedu.com/asrt_automatic_exposure_control.htm. 38.J C Le Heron et al., Estimation of effective dose to the patient during medical X-ray examinations from measurements of the dose-area product. Phys. Med. Biol. 1992, 37(11) 2117-2126,. 39.European commission, European guidelines on quality criteria for diagnostic radiographic images. 1996 SBN 92-827-7284-5. 40.Harrell G. Chotas, James T. DobbinsⅢ, Carl E. Ravin, Principles of digital radiography with large-area, electronically readable detectors: a review of basics. Radiology 210:595-599, 1999.
|