|
[1] J. M. Reijn, and H. Poppe, “A Possible Approach to the Optimization of Flow Injection Analysis.” Anal. Chim. Acta, 145 (1983) 59-70.
[2] S. D. Kolev, “Mathematical Modelling of Flow-Injection System.” Anal. Chim. Acta, 308 (1995) 36-66.
[3] J. Ruzicka, and E. H. Hansen, “Flow Injection Analysis.” 2nd ed, Wiley, New York, Chichester, Brisbane, Toronto, Singapore, 1988.
[4] W. E. van der Linden, “Flow Injection Analysis;the Manipulation of Dispersion.” Tr. Anal. Chem., 1, 8 (1982) 188-191.
[5] M. J. E. Golay, and J. G. Atwood, “Early Phases of the Dispersion of a Sample Injected in Poiseuille Flow.” J. Chromatogr., 186 (1979) 353-370.
[6] D. C. Stone, and J. F. Tyson, “Flow Cell and Diffusion Coefficient Effects in Flow Injection Analysis.” Anal. Chim. Acta., 179 (1986) 427-432.
[7] D. C. Stone, and J. F. Tyson, “Effect of Flow Cell on Dispersion in Flow Injection Analysis.” Anal. Proc., 23 (1986) 23-26.
[8] S. D. Kolev, and E. Pungor, “End Effect in Flow-Analysis and Process Systems.” Talanta, 34 (1987) 1009-1014.
[9] S. D. Kolev, and E. Pungor, “Mathematical Modelling of Single-Line Flow-Injection Analysis System without Chemical Reaction.” Anal. Chem., 60 (1988) 1700-1709. [10] J. P. Foley, and J. G. Dorsey, “A Review of the Exponential Modified Gaussian (EMG) Function: Evaluation and Subsequent Calculation of Universal Data.” J. Chromatogr. Sci., 22 (1984) 40-46.
[11] D. Hanggi, and P. Carr, “Errors in Exponentially Modified Gaussian Equations in the Literature.” Anal. Chem., 57 (1985) 2394-2395.
[12] J. P. Foley, and J. G. Dorsey, “Equations for Calculation of Chromatographic Figures of Merit for Ideal and Skewed Peaks.” Anal. Chem., 55 (1983) 730-737.
[13] J. P. Foley, “Equations for Chromatographic Peak Modeling and Calculation of Peak Area.” Anal. Chem., 59 (1987) 1984-1987.
[14] O. Levenspiel, “Chemical Reaction Engineering.” Wiley, New York, 1962.
[15] B. L. Karger, L. R. Snyder, and Cs. Horvath, “An Introduction to Separation Science.” Wiley, New York, 1973.
[16] H. Poppe, “Characterization and Design of Liquid Phase Flow Through Detector System.” Anal. Chim. Acta, 114 (1980) 59-70.
[17] B. F. Johnson, R. E. Malick, and J. G. Dorsey, “Reduction of Injection Variance in Flow Injection Analysis.” Talanta, 39 (1992) 35-44.
[18] S. H. Brooks, D. V. Leff, M. A. Hernandez Torres, and J. G. Dorsey, “Dispersion Coefficient and Moment Analysis of Flow Injection Analysis Peaks.” Anal. Chem., 60 (1988) 2737-2744. [19] J. M. Rejin, W. E. van der Linden, and H. Poppe, “Some Theoretical Aspects of Flow Injection Analysis.” Anal. Chim. Acta, 114 (1980) 105-118.
[20] S. C. Pai, “Evaluation of the Temporal Effect to the Peak Tailing in Flow Injection Analysis.” J. Chromatogr. A, 950 (2002) 271-279.
[21] S. C. Pai, “Parcel Model for Peak Shapes in Chromatography-Numerical Verification of the Temporal Distortion Effect to Peak Asymmetry.” J. Chromatogr. A, 988 (2003) 233-260.
[22] S. C. Pai, “Temporally Convoluted Gaussian Equations for Chromatographic Peaks.” J. Chromatogr. A, 1028 (2004) 89-103.
[23] S. C. Pai, and L. Y. Chiao, “Temporal Shifting:A Key to the Skewed Peak Puzzle.” submitted to J. Chromatogr. A, (2004) (Personal communication)
[24] G. A. Korn, and T. M. Korn, “Mathematical Handbook.” McGraw-Hill, New York, 1968.
[25] Pai, 2005 (Personal communication).
[26] P. W. Atkins, “Physical Chemistry.” sixth edition, Oxford, New York, 1988.
[27] G. I. Taylor, “Dispersion of Soluble Matter in Solvent Flowing Slowly Through a Tube.” Proc. Roy. Soc. A, 219 (1953) 186-203.
[28] G. I. Taylor, “The Dispersion of Matter in Turbulent Flow Through a Pipe.” Proc. Roy. Soc. A, 223 (1954) 446-468.
[29] R. Tijssen, “Axial Dispersion and Flow Phenomena in Helically Coiled Tubular Reactors for Flow Analysis and Chromatography.” Anal. Chim. Acta, 114 (1980) 71-89.
[30] J. M. Rejin, W. E. van der Linden, and H. Poppe, “Transport Phenomena in Flow Injection Analysis without Chemical Reaction.” Anal. Chim. Acta, 126 (1981) 1-13.
[31] J. M. Rejin, W. E. van der Linden, and H. Poppe, “Dispersion in Open Tube and Tubes Packed with Large Glass Beads.” Anal. Chim. Acta, 123 (1981) 229-237.
[32] J. H. M. van den Berg, R. S. Deelder, and H. G. M. Egberink, “Dispersion Phenomena In Reactor For Flow Analysis.” Anal. Chim. Acta, 114 (1980) 91-104.
[33] 海化實驗報告選輯, 台灣大學海洋研究所化學組, vol.3 (1991) 60-61
|