[1] 張寶樹,“放射治療物理學”,合記圖書出版社 (2004).
[2] Johnson, M.W., Griggs, M.A., Sharma, S.C., “A Comparison of Surface Doses for Two Immobilizing Systems,” Med. Dosim. 20, 191–194 (1995).
[3] Tsang, C., Martin, J.B., Peter, K.N.Yu., “Evaluation of Build-up Dose from 6 MV X-rays under Pelvic and Abdominal Patient Immobilization Devices,” Radiation Measurements, 35, 235-238 (2002).
[4]http://www.sinmed.nl/html/products/products_carbonfiber_inserts.html
[5] Ost, B.D., Vanregemorter, J., Shaeken, B., Van den Weyngaert, D., “The Effect of Carbon Fiber Inserts on the Build-up and Attenuation of High Energy Hhoton Beams,” Radiother. Oncol. 45, 275–277 (1997).
[6] Higgins, D.M., Whitehurst, P., Morgan, A.M., “The Effect of Carbon Fiber Couch Inserts on Surface Dose with Beam Size Variation,” Med. Dosim. 26, 251–254 (2001).
[7] AAPM TG21, “A Protocol for the Determination of Absorbed Dose from High Energy Photon and Electron Beams,” Med. Phys. 10, 741–771 (1983).
[8] AAPM TG51, “A Protocol for Clinical Reference Dosimetry of High-Energy Photon and Electron Beams,” Med. Phys. 26, 1847–1870 (1999).
[9] Turner, J.E., “Atoms, Radiation, and Radiation Protection,” 2nd ed. John Wiley & Son,
Inc., New York (1995).
[10] Khan, F.M., “The Physics of Radiation Therapy,” 3rd ed. Lippincott Williams and Wilkins, USA (2003).
[11] 王慧娟,“頭頸部放射治療的活體劑量驗證”,清華大學碩士論文 (2001).[12] 陳永泰,“熱發光劑量計對同步輻射光回應” ,清華大學碩士論文 (1996).[13] 林源山,“核子醫學之線上體內劑量評估” ,清華大學碩士論文 (2004).[14] Veld, A.A., “Analysis of Accuracy in Dose and Position in Calculations of a Treatment Planning System for Blocked Photon Fields,” Radiother. Oncol. 45, 245–251 (1997).
[15] Harms, W.B., Low, D.A., Wong, J.W., Purdy, J.A., “A Software Tool for the Quantitative Evaluation of 3D Dose Calculation Algorithms,” Med. Phys. 25, 1830–1836 (1998).
[16] 林松彥,“放射治療旋繞疊加劑量演算法之準確度評估” ,清華大學博士論文 (2002).[17] International Commission on Radiation Units and Measurements. “Prescribing, Recording, and Reporting Photon Beam Therapy,” ICRU Report 50 (1993).
[18] International Commission on Radiation Units and Measurements. “Prescribing, Recording, and Reporting Photon Beam Therapy (Supplement to ICRU Report 50),” ICRU Report 62 (1999).
[19] AAPM Radiation Therapy Committee TG53, “Quality Assurance Program for Radiotherapy Treatment Planning,” Med. Phys. 25, 1773-1836 (1998).
[20] Venselaar, J., Welleweerd, H., Mijnheer, B., “Tolerances for the Accuracy of Photon Beam Dose Calculations of Treatment Planning Systems,” Radiother. Oncol. 60, 191–201 (2001).
[21] Martens, C., Reynaert, N., Nilsson,P., et. al., “Underdosage of the Upper-Airway Mucosa for Small Fields as used in IMRT : A Comparison Between Radiochromic Film Measurements, Monte Carlo Simulations, and Collapsed Cone Convolution Calculations,” Med. Phys. 29, 1528–35 (2002).
[22] Aspradakis, M.M., Morrison, R.H., Richmond, N.D., “Experimental Verification of Convolution/superposition Photon Dose Calculations for Radiotherapy Treatment Planning,” Phys. Med. Biol. 48, 2873-2893 (2003).
[23] Radiation Therapy Oncology Group, “A Phase I/II Dose Escalation Study Using Three Dimensional Conformal Radiation Therapy For Adenocarcinoma of the Prostate,” RTOG 94-06 (2000).
[24] Radiation Therapy Oncology Group, “A Phase III Randomized Study of High Dose 3D-CRT/IMRT versus Standard Dose 3D-CRT/IMRT in Patients Treated for Localized Prostate Cancer,” , RTOG 0126 (2006).
[25] Lee, N., Chuang, C., Quivey, J. M., et. al., “Skin Toxicity Due To Intensity-Modulated
Radiotherapy for Head-and-Neck Carcinoma,” Int. J. Radiation Biol. Phys., 53, 630–637 (2002).