[1] N. Takasu, T. Oshi, F. Miyawaki, S. Saito, and Y. Fujiwara, " An experimental analysis of DC Excitation of Transformers by Geomagnetically Induced Currents " , IEEE Trans. Power Delivery , vol. 9, pp. 1173-1182, 1994.
[2] L. Trichtchenko, and D.H. Boteler, " Effects of Recent Geomagnetic Storms on Power Systems " , Electromagnetic Compatibility and Electromagnetic Ecology International Symposium on 26-29 , pp. 265-268, 2007.
[3] P. R. Price, " Geomagnetically induced current effects on transformers " , IEEE Trans. Power Delivery , vol. 17, pp. 1002-1008, 2002.
[4] S. Lu, and Y. Liu, " FEM analysis of DC saturation to assess transformer susceptibility to geomagnetically induced currents ", IEEE Trans. Power Delivery , vol. 8 , pp. 1367-1376, 1993
[5] E.F. Fuchs, Y. You, and D.J. Roesler, " Modeling and simulation, and their validation of three-phase transformers with three legs under DC bias " , IEEE Trans. Power Delivery , vol. 14 , pp. 443-449 , 1999.
[6] Lin Cao, Jie Zhao, and Jinliang He, " Improved Power Transformer Model for DC Biasing Analysis Considering Transient Leakage Reluctances " , International Conference on Power System Technology , pp. 1-5 , 2006.
[7] L. Bolduc, A. Dutil, VQ Pham, and P. Picher, " Study of the Acceptable DC Current Limit in Core-Form Power Transformers " , IEEE Trans. Power Delivery , vol. 12 , pp. 257-265, 1997.
[8] L.B. Sipahi, " Influence of DC bias field, excitation and detection frequencies on magnetic Barkhausen noise analysis " , IEEE Transactions on vol. 30 , Magnetics , pp. 4590-4592 , 1994.
[9] O. Biro, S. Ausserhofer, and G. Buchgraber, K. Preis, and W. Seitlinger,
" Prediction of magnetizing current waveform in a single-phase power transformer under DC bias " , Measurement and Technology , Science , IET Vol. 1 , pp. 2-5 , 2007.
[10] 林忠正,以EMTP做一次變電所主變壓器激磁特性模擬分析,中原大學電機工程學系碩士班碩士論文,中華民國九十二年。[11] 陳勵生,同直流偏壓下對25KVA非晶質鐵心變壓器的影響分析與測試,中原大學電機工程學系碩士班碩士論文,中華民國九十一年。[12] 張耀仁,高頻變壓器之鐵心特性探討,中原大學電機工程學系碩士班碩士論文,中華民國九十二年。[13] B. Leonard, G. Michel, P. Gregoire, and et., " Development of a DC Current-Blocking Device for Transformer Neutrals " , IEEE Trans. Power Delivery , vol. 20 , pp. 163-168, 2005.
[14] Z. Du, X. Dong, J. Wang, and Z. He, " Test and Analysis on Restraining Transformer DC Bias by CHANGING Electric Potential of Grounding Grid " , High Voltage Engineering , vol.32 , pp. 69-72, 2006.
[15] C.A. Baguley, B. Carsten, and U.K. Madawala, " The Effect of DC Bias Conditions on Ferrite Core Losses " , IEEE Transactions on vol. 44 , Magnetics , pp. 246-252, 2008.
[16] Q. Li, F.C. Lee, and M.M. Jovanovic, " Design considerations of transformer DC bias of forward converter with active-clamp reset " , Applied Power Electronics Conference and Exposition , pp. 553-559, 1999.
[17] R. Pirjola, ” Geomagnetically induced currents during magnetic storms " , IEEE Transactions on vol.28., Plasma Science , pp. 1867-1873 , 2000.
[18] 林展弘,單相變壓器激磁電流之諧波特性與磁滯迴線之研究,中原大學電機工程學系碩士班碩士論文,中華民國九十一年。[19] 鄭至焜,應用非對稱線圈結構降低變壓器湧入電流之研究,成功大學電機工程學系博士班博士論文,中華民國九十三年。[20] 大同技術委員會,大同變壓器的製造與試驗,大同技術手冊電力技術篇第二冊,中華民國六十六年。
[21] 大同技術委員會,大同變壓器的特性與構造,大同技術手冊電力技術篇第一冊,中華民國六十六年。