De Hauwere A, Bacher K, Smeets P, Koenraad V and Thierens H 2005 Analysis of
image quality in digital chest imaging Rad Prot Dosim 117 174–177
Elimpex-Medizintechnik “QA equipment Manual” 15-16
Floyd C E, Baker J A, Lo J Y and Ravin C E 1992 Measurement of scatter fractions in
clinical bedside radiology Radiology 183 857–861
Floyd C E, Warp R J, Dobbins III J T, Chotas H G, Baydush A H, Vargas-Voracek R
and Ravin C E 2001 Imaging characteristics of an amorphous silicon
flat-panel detector for digital chest radiography Radiology 218 683–688
Jordan III L K, Floyd C E, Lo J Y and Ravin C E 1993 Measurement of scatter
fractions in erect posteroanterior and lateral chest radiography Radiology
188 215–218
Kotter E, Langer M 2002 Digital radiography with large-area flat-panel detectors Eur
Radiol 12 2562–2570
Lo J Y, Floyd C E, Baker J A and Ravin C E 1994 Scatter compensation in digital
chest radiography using the posterior beam stop technique Med. Phys. 21
435–443
Mah E, Samei E and Peck DJ 2001 Evaluation of a quality control phantom for digital
chest radiography J Appl Clin Med Phys 2 90-101
Neitzel U 1992 Grids or air gaps for scatter rejection in digital radiography: A model
calculation Med. Phys. 19 475–481
Niklason L T, Sorenson J A and Nelson J A 1981 Scattered radiation in chest
radiography Med. Phys. 8 677–681
Norrman E, Gardestig M, Persliden J and Geijer H 2005 A clinical evaluation of the
image quality computer program CoCIQ J Digit Imaging 18 138-144
Partridge M, Hesse B M and Muller L 2002 A performance comparison of direct- and
indirect-detection flat-panel imagers Nucl. Instrum 484 351–363
Papp J 1998 Quality management in the imaging sciences 77-97
Pascoal A, Lawinski C P, Honey I and Blake P 2005 Evaluation of a software package
for automated quality assessment of contrast detail images - comparison
with subjective visual assessment Phys Med Biol. 50 5743-5757
Quality Control Manual MAMMOMAT Novation DR
Rong X J, Shaw C C, Liu X, Lemacks M R and Thompson S K 2001 Comparison of
an amorphous silicon/cesium iodide flat-panel digital chest radiography
system with screen/film and computed radiography system: A
contrast-detail phantom study Med. Phys. 28 2328–2335
Spahn M, Strotzer M, Voelk M, Boehm S, Geiger B, Hahm G and Feuerbach S 2000
Digital radiography with a large-area, amorphous-silicon flat panel X-ray
detector system Invest Radiol 35 260–266
Thijssen M A O, Bijkerk K R and van der Burght R J M 1998 Manual contrast-detail
phantom CDRAD type 2.0. Project Quality Assurance in Radiology,
Section Clinical Physics, Department of Radiology, University Hospital
Nijmegen, St Radboud
莊克士 “醫學影像物理學” 合記書局 1998
翁寶山 ”最新放射物理學” 新竹黎明書店總經銷 1984
施名原 “使用對比解析板評估數位化X光機之最優化” 國立清華大學碩士論文2006
黃增德 “電腦程式分析X光照像之影像品質的研究” 國立清華大學碩士論文 2007