ASTM E976-00. (2000). Standard Guide for Determining the Reproducibility of Acoustic Emission Sensor Response. Chen, J. F., Tai, C. C., Liang, T. J., Su, C. C., Yi, C. S., & Chen, C. Y. (2008). High-voltage transformer coil with acoustic wave guiding function. US Patent 7339447. Gockenbach, E., Werle, P., & Borsi, H. (2001). Monitoring and diagnostic systems for dry type transformers. IEEE 7th International Conference on Solid Dielectrics , pp. 291-294. Harrold, R. T. (1979). Acoustic Waveguides for Sensing and Locating Electrical Discharges in High Voltage Power Transformers and Other Apparatus. IEEE Transactions on Power Apparatus and Systems , 98, pp. 449-457. Harrold, R. T. (1985). Acoustical Technology Applications in Electrical Insulation and Dielectrics. IEEE Transactions on Electrical Insulation , 20, pp. 3-19. IEEE Std C57.124-1991. (1992). IEEE recommended practice for the detection of partial discharge and the measurement of apparent charge in dry-type transformers. Kweon, D. J., Chin, S. B., Kwak, H. R., Kim, J. C., & Song, K. B. (2005). The Analysis of Ultrasonic Signals by Partial Discharge and Noise From the Transformer. IEEE Transactions on Power Delivery , 20, pp. 1976-1983. Lundgaard, L. E. (1992). Partial discharge. XIV. Acoustic partial discharge detection-practical application. IEEE Electrical Insulation Magazine , 8, pp. 34-43. H, Lamela-Rivera., C, Macia-Sanahuja., & J, A. Garcia-Souto. (2003). Detection and wavelet analysis of partial discharges using an optical fibre interferometric sensor for high-power transformers. J. Opt. A: Pure Appl. Opt , 5, pp. 66-72. Prosser, W. H., & Gorman, M. R. (1994). Accurate Simulation of Acoustic Emission Sources in Composite Plates. ASNT Spring Conference New Orleans. Ronald, T. H., & Murrysville, Pa. (1979). Acoustic waveguides for sensing and locating corona discharges. US Patent 4158168. Skubis, J. (1982). Piezoelectric reflecting transducer for partial discharge acoustic signals. Journal of Physics E: Scientific Instruments , 15, pp. 1022-1026. Smith, G. C. (2005). A noncontact method for detecting acoustic emission using a microwave Doppler radar motion detector. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control , 52, pp. 1613-1617. Su, C. C., Tai, C. C., Chen, J. F., Chen, C. Y., & Hsieh, J. C. (2008). Partial Discharge Detection Using Acoustic Emission Method for a Waveguide Functional High-Voltage Cast-Resin Dry-Type Transformer. International Conference on Monitoring and Diagnosis, Beijing, China. User’s guide. TransiNor As. (2003). Diagnostic Instrument From TransiNor As,AIA-1. Vellucci, E., Cavallini, A., Montanari, G. C., & Fabiani, D. (2004). Experience on partial discharge monitoring of power transformers. IEEE International Symposium on Elechical Insularion , pp. 174-177. Werle, P., Wasserberg, V., Borsi, H., & Gockenbach, E. (2000). New devices for a dry type transformer protection and monitoring system. Properties and Applications of Dielectric Materials, 2000. Proceedings of the 6th International Conference on , 1, pp. 567-570. Werle, P., Wasserberg, V., Borsi, H., & Gockenbach, E. (2000), A new protection and monitoring system for dry type transformers based on innovative sensor technologies. IEEE International Symposium on Electrical Insulation , pp. 255-258. Werle, P., Borsi, H., & Gockenbach, E. (2002). Diagnosing the insulation condition of dry type transformers using a multiple sensor partial discharge localization technique. IEEE International Symposium on Electrical Insulation , pp. 166-169. Wu, R. N., & Lin, Y. H. (2004). Estimating the aging trend of dry-type currenttransformer Journal of the Chinese Institute of Engineers, 27, pp. 69-77. Xiaodong, W., Baoqing, L., Zhixiong, X., Sang, H. L., Harry, Roman., Onofrio, L. R., Ken, K. C., & Kenneth, R. F. (2005). An ultra-sensitive optical MEMS sensor for partial discharge detection. J. Micromech. Microeng , 15, pp. 521-527. 蘇經洲、戴政祺、陳建富、殷偉綸、洪銘良和李耀郎 (2006)。具音波傳導功能之高壓模鑄型變壓器。第二十七屆電力工程研討會。 蘇經洲、劉顯成、林育蓉、易經順、陳建富、梁從主和戴政祺 (2004)。模鑄型變壓器部分放電信號之音射法檢測。第十二屆非破壞檢測技術研討會。
|