[1]United Nations, Department of Economic and Social Affairs, Population Division (2015). World Population Prospects: The 2015 Revision, Key Findings and Advance Tables. Working Paper No. ESA/P/WP.241.
[2]Raez, M.B.I., M.S. Hussain, and F. Mohd-Yasin. “Techniques of EMG Signal Analysis: Detection, Processing, Classification and Applications,” Biological Procedures Online 8 (2006), pp. 11–35, Aug. 2016.
[3]Marcus Vollmer, A Robust, “Simple and Reliable Measure of Heart Rate Variability using Relative RR Intervals,” 2015 Computing in Cardiology Conference (CinC), pp. 609-612 , 2015.
[4]D. Tepavac, Z. Nikolic , “A PORTABLE 8 CHANNEL SURFACE EMG RECORDING SYSTEM,” Engineering in Medicine and Biology Society, 1992 14th Annual International Conference of the IEEE, Volume: 4, pp. 1433 – 1434, 1992.
[5]Mirjana Popović, “A portable 8 channel gait kinematics recording unit,” Engineering in Medicine and Biology Society, 1992 14th Annual International Conference of the IEEE, pp. 1646 – 1647, Nov. 1992.
[6]Maged S. Al-Quraishi, “Multichannel EMG data acquisition system: Design and temporal analysis during human ankle joint movements,” Biomedical Engineering and Sciences (IECBES), 2014 IEEE Conference on, pp. 338 – 342, 2014.
[7]Daniel Johansen, “Control of a Robotic Hand Using a Tongue Control System—A Prosthesis Application,” IEEE Transactions on Biomedical Engineering , Volume:63 Issue: 7, July 2016.
[8]曾均涵,不同收縮模式肌肉疲勞對力矩與肌電圖訊號變化之影響,碩士論文,國立臺灣體育大學,桃園,2009。[9]A. J. Cook,G. D. Gargiulo,T. Lehmann,T. J. Hamilton, “Open platform, eight-channel, portable bio-potential and activity data logger for wearable medical device development,” Electronics Letters (Volume:51 , Issue: 21 ), pp. 1127-1129, 2014.
[10]Jesus Efrain Gaxiola-Sosa, “A portable 12-lead ECG wireless medical system for continuous cardiac-activity monitoring,” 2nd Middle East Conference on Biomedical Engineering, pp. 123 – 126, Feb. 2014.
[11]Chin-Tang Hsieh, “A Holter of Low Complexity Design Using Mixed Signal Processor,” Fifth IEEE Symposium on Bioinformatics and Bioengineering (BIBE05), pp. 316-319, Oct. 2005.
[12]FELIPE P CARPES, CARLOS B MOTA, IRVIN E FARIA , “HEART RATE RESPONSE DURING A MOUNTAIN-BIKE EVENT: A CASE REPORT,” Journal of Exercise Physiology online, Volume 10 Number 1, February 2007.
[13]Joseph D. Bronzino, “The Biomedical Engineering Handbook,” CRC Press; 2 edition, December, 2000.
[14]AD8232: Single-Lead, Heart-Rate Monitor Front End Data Sheet (Rev. A), ANALOG DEVICE, http://www.analog.com, June, 2016.
[15]Single Lead Heart Rate Monitor - AD8232 Hook-up guide, SparkFun, https://www.sparkfun.com/, June, 2016..
[16]MyoWare Muscle Sensor user’s manual, SparkFun, https://www.sparkfun.com/ , June, 2016.
[17]NEO-6 u-blox 6 GPS Modules Data Sheet, u-blox, https://www.u-blox.com, June, 2016.
[18]u-blox6 Receiver Description Protocol Specification, u-blox, https://www.u-blox.com, April, 2013.
[19]Google Maps, https://maps.google.com/, June, 2016.
[20]Google Earth, https://earth.google.com/, June, 2016.
[21]dsPIC33EP512MU810, Microchip Microprocessor Datasheet, http://www.microchip.com, Oct. 2012.
[22]SD Specifications Part 1 Physical Layer Simplified Specification Version 4.10, January 22, 2013.
[23]Maël Hörz., HxD - Freeware Hex Editor and Disk Editor, https://mh-nexus.de/en/hxd/ , June, 2016.
[24]Garmin Proprietary NMEA 0183 Sentences TECHNICAL SPECIFICATIONS, Garmin International, Inc., 190-00684-00, Revision C, December 2008.
[25]MPLAB C Compiler for PIC24 MCUs and dsPIC DSCs, Microchip, http://www.microchip.com, June, 2016.
[26]MPLAB® X Integrated Development Environment (IDE), Microchip, http://www.microchip.com, June, 2016.
[27]PICkit 3 Programmer/Debugger Users Guide, Microchip, http://www.microchip.com, June, 2010.
[28]Peter Reen, “Implementing File I/O Functions Using Microchip’s Memory Disk Drive File System Library,” Microchip Technology Inc., 2007.
[29]EDFbrowser universal viewer and toolbox, http://www.teuniz.net/edfbrowser/index.html, June, 2016.
[30]Robert B. Northrop, “Analysis and Application of Analog Electronic Circuits to Biomedical Instrumentation,” CRC Press LLC, 2004.
[31]黃天守、陳清輝譯,基本心電圖判讀,台北:眾文圖書公司,1991。
[32]Ibrahim Abdullahi Karaye, “Analysis of cardiac beats using higher order spectra,” 2014. IEEE 6th International Conference on Adaptive Science & Technology (ICAST), pp.1-8, 2014.
[33]u-center Windows GNSS evaluation software for Windows, u-blox, https://www.u-blox.com/en, June, 2016.
[34]NCR18650 Li-Lion Battery Catalog, Panasonic, http://industrial.panasonic.com, June, 2016.
[35]European Data Format - EDF , http://www.edfplus.info/index.html, June, 2016.