|
[1] E. J. Benjamin et al., "Heart Disease and Stroke Statistics-2017 Update: A Report From the American Heart Association," Circulation, vol. 135, no. 10, p. e146, 2017. [2] 中華民國衛生福利部(2018). Available: https://www.mohw.gov.tw/mp-1.html (accessed on 6 December 2018) [3] S. Yusuf et al., "Effect of potentially modifiable risk factors associated with myocardial infarction in 52 countries (the INTERHEART study): case-control study," The lancet, vol. 364, no. 9438, pp. 937-952, 2004. [4] P. D. Richardson, M. Davies, and G. Born, "Influence of plaque configuration and stress distribution on fissuring of coronary atherosclerotic plaques," The Lancet, vol. 334, no. 8669, pp. 941-944, 1989. [5] M. Naghavi et al., "From vulnerable plaque to vulnerable patient: a call for new definitions and risk assessment strategies: Part I," circulation, vol. 108, no. 14, pp. 1664-1672, 2003. [6] S. W. Cheng, A. C. Ting, and J. Wong, "Endovascular stenting of superficial femoral artery stenosis and occlusions: results and risk factor analysis," Cardiovascular Surgery, vol. 9, no. 2, pp. 133-140, 2001. [7] L. Cho, M. Roffi, D. Mukherjee, D. L. Bhatt, C. Bajzer, and J. S. Yadav, "Superficial femoral artery occlusion: nitinol stents achieve better flow and reduce the need for medications than balloon angioplasty alone," The Journal of invasive cardiology, vol. 15, no. 4, pp. 198-200, 2003. [8] T. W. Duerig, A. Pelton, and D. Stöckel, "An overview of nitinol medical applications," Materials Science Engineering: A, vol. 273, pp. 149-160, 1999. [9] Medtronic. Balloon- Expandable stents. Available: http://www.igiasi.gr/balloon-expandable-stents-visi-pro-paramount-mini/ (accessed on 6 December 2018) [10] Global Peripheral Vascular Stents Market 2018 – Abbott Laboratories. Self Expanding Stent. Available: http://legmannews.com/global-peripheral-vascular-stents-market-2018/ (accessed on 6 December 2018) [11] A. R. Pelton, V. Schroeder, M. R. Mitchell, X. Y. Gong, M. Barney, and S. W. Robertson, "Fatigue and durability of Nitinol stents," Journal of the Mechanical Behavior of Biomedical Materials, vol. 1, no. 2, pp. 153-164, 2008. [12] Garcia-Toca, Manuel et al., "Are carotid stent fractures clinically significant?," Cardiovascular interventional radiology, vol. 35, no. 2, pp. 263-267, 2012. [13] L. Petrini, W. Wu, E. Dordoni, A. Meoli, F. Migliavacca, and G. Pennati, "Fatigue behavior characterization of nitinol for peripheral stents," Functional Materials Letters, vol. 5, no. 01, p. 1250012, 2012. [14] D. Scheinert et al., "Prevalence and clinical impact of stent fractures after femoropopliteal stenting," Journal of the American College of Cardiology, vol. 45, no. 2, pp. 312-315, 2005. [15] M. Grujicic, B. Pandurangan, A. Arakere, and J. S. Snipes, "Fatigue-Life Computational Analysis for the Self-Expanding Endovascular Nitinol Stents," Journal of Materials Engineering and Performance, vol. 21, no. 11, pp. 2218-2230, 2012. [16] J. M. Gibbs, C. S. Peña, and J. F. Benenati, "Treating the diseased superficial femoral artery," Techniques in vascular interventional radiology, vol. 13, no. 1, pp. 37-42, 2010. [17] X. Gong, D. Chwirut, M. Mitchell, and B. Choules, "Fatigue to fracture: an informative, fast, and reliable approach for assessing medical implant durability," in Fatigue and Fracture of Medical Metallic Materials and Devices: 2nd Volume: ASTM International, 2010. [18] S. E. Lee et al., "Clinical outcomes and optimal treatment for stent fracture after drug-eluting stent implantation," Journal of cardiology, vol. 53, no. 3, pp. 422-428, 2009. [19] O. W. Bertacchini, C. Lagoudas, F. Calkin, and J. H. Mabe, "Transformation induced cyclic behavior and fatigue properties of nickel rich NiTi shape memory alloy actuators," in Proceedings of the ICOMAT, vol. 8. ,2008. [20] X. Yan, D. Yang, and X. Liu, "Influence of heat treatment on the fatigue life of a laser-welded NiTi alloy wire," Materials Characterization, vol. 58, no. 3, pp. 262-266, 2007. [21] H. M. Hsiao, Y. H. Chiu, K. H. Lee, and C. H. Lin, "Computational modeling of effects of intravascular stent design on key mechanical and hemodynamic behavior," Computer-Aided Design, vol. 44, no. 8, pp. 757-765, 2012. [22] H. M. Hsiao, L. W. Wu, M. T. Yin, C. H. Lin, and H. Chen, "Quintupling fatigue resistance of intravascular stents via a simple design concept," Computational Materials Science, vol. 86, pp. 57-63, 2014. [23] H. M. Hsiao and M. T. Yin, "An intriguing design concept to enhance the pulsatile fatigue life of self-expanding stents," Biomedical microdevices, vol. 16, no. 1, pp. 133-141, 2014. [24] G. Alaimo, F. Auricchio, M. Conti, and M. Zingales, "Multi-objective optimization of nitinol stent design," Medical engineering & physics, vol. 47, pp. 13-24, 2017. [25] D. Allegretti, F. Berti, F. Migliavacca, G. Pennati, and L. Petrini, "Fatigue Assessment of Nickel–Titanium Peripheral Stents: Comparison of Multi-Axial Fatigue Models," Shape Memory and Superelasticity, vol. 4, no. 1, pp. 186-196, 2018. [26] X. Y. Gong, A. R. Pelton, T. W. Duerig, N. Rebelo, and K. Perry, "Finite element analysis and experimental evaluation of superelastic Nitinol stent," in SMST–2003 Proc. International Conference on Shape Memory and Superelastic Technologies, pp. 453-462: SMST Society, Menlo Park, CA., 2004 [27] H. M. Hsiao, "Why similar stent designs cause new clinical issues," JACC: Cardiovascular Interventions, vol. 5, no. 3, p. 362, 2012. [28] H. M. Hsiao, K. H. Lee, Y. C. Liao, and Y. C. Cheng, "Cardiovascular stent design and wall shear stress distribution in coronary stented arteries," IET Micro Nano Letters, vol. 7, no. 5, pp. 430-433, 2012. [29] R. Rieu et al., "Radial force of coronary stents: a comparative analysis," Catheterization Cardiovascular Interventions, vol. 46, no. 3, pp. 380-391, 1999. [30] ABAQUS UMAT for Superelasticity and Plasticity of Shape Memory Alloys document. [31] F. Auricchio, "A robust integration-algorithm for a finite-strain shape-memory-alloy superelastic model," International Journal of plasticity, vol. 17, no. 7, pp. 971-990, 2001. [32] F. Auricchio and R. L. Taylor, "Shape-memory alloys: modelling and numerical simulations of the finite-strain superelastic behavior," Computer methods in applied mechanics engineering, vol. 143, no. 1-2, pp. 175-194, 1997. [33] M. Eriksen, "Effect of pulsatile arterial diameter variations on blood flow estimated by Doppler ultrasound," Medical Biological Engineering Computing, vol. 30, no. 1, pp. 46-50, 1992. [34] Guide for Radial Loading of Balloon Expandable and Self Expanding Vascular Stents. [35] R. N. Ghriallais and M. Bruzzi, "Self-expanding stent modelling and radial force accuracy," Computer methods in biomechanics biomedical engineering, vol. 17, no. 4, pp. 318-333, 2014. [36] U. FDA, "Guidance for industry and FDA staff. Non-clinical tests and recommended labeling for intravascular stents and associated delivery systems," ed, 2007. [37] T. M. Pham, M. DeHerrera, and W. Sun, "Analysis and simulation of PTMA device deployment into the coronary sinus: Impact of stent strut thickness," in Mechanics of Biological Systems and Materials, Volume 2: Springer, pp. 1-10., 2011. [38] P. Adler, J. Allen, J. Lessar, and R. Francis, "Martensite transformations and fatigue behavior of nitinol," in Fatigue and fracture of medical metallic materials and devices: ASTM International, 2007. [39] T. Duerig, D. Tolomeo, and M. Wholey, "An overview of superelastic stent design," Minimally Invasive Therapy & Allied Technologies, vol. 9, no. 3-4, pp. 235-246, 2000. [40] Z. Lin and A. Denison, "Nitinol fatigue resistance–a strong function of surface quality," in Medical Device Materials: Proceeding of the Materials & Processes for Medical Devices Conference, pp. 205-208., 2004. [41] Z. Lin, H. M. Hsiao, D. Mackiewicz, B. Anukhin, and K. Pike, "Anisotropic behavior of radiopaque NiTiPt hypotube for biomedical applications," Advanced Engineering Materials, vol. 11, no. 11, pp. B189-B193, 2009. [42] 陳金壽, "應用位置同步輸出之觸發控制雷射於銦錫氧化物薄膜微加工," 2012. [43] K. Otsuka and X. Ren, "Recent developments in the research of shape memory alloys," Intermetallics, vol. 7, no. 5, pp. 511-528, 1999.
[44] A. R. Pelton, J. Dicello, and S. Miyazaki, "Optimisation of processing and properties of medical grade Nitinol wire," Minimally Invasive Therapy Allied Technologies, vol. 9, no. 2, pp. 107-118, 2000. [45] M. J. Drexel, "The effects of cold work and heat treatment on the properties of nitinol wire," 2006. [46] P. R. Miller, R. Aggarwal, A. Doraiswamy, Y. J. Lin, Y. S. Lee, and R. J. Narayan, "Laser micromachining for biomedical applications," Jom, vol. 61, no. 9, pp. 35-40, 2009. [47] 柯俊誼, "鎳鈦合金於植入式醫療器材上的多種應用,", 2016. [48] B. Clarke, W. Carroll, Y. Rochev, M. Hynes, D. Bradley, and D. Plumley, "Influence of nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release," Journal of Biomedical Materials Research Part A: An Official Journal of The Society for Biomaterials, The Japanese Society for Biomaterials, The Australian Society for Biomaterials the Korean Society for Biomaterials, vol. 79, no. 1, pp. 61-70, 2006. [49] T. Hahn and A. Marder, "Effect of electropolishing variables on the current density-voltage relationship," Metallography, vol. 21, no. 4, pp. 365-375, 1988. [50] 陳貽和, "電化學陽極溶解反應模型研究,", 2013. [51] C. Chu et al., "Surface structure and biomedical properties of chemically polished and electropolished NiTi shape memory alloys," Materials Science Engineering: C, vol. 28, no. 8, pp. 1430-1434, 2008. [52] Á. Lengyel, P. Nagy, E. Bognár, and K. Hirschberg, "Development of Nitinol stents: electropolishing experiments," in Materials Science Forum, vol. 729, pp. 436-441: Trans Tech Publ., 2013. [53] K. Otsuka and C. Wayman, "Mechanism of shape memory effect and superelasticity," Shape memory materials, pp. 27-49, 1998. [54] T. W. Duerig, K. Melton, and D. Stöckel, Engineering aspects of shape memory alloys. Butterworth-Heinemann, 2013. [55] H. Tobushi, T. Hachisuka, T. Hashimoto, and S. Yamada, "Cyclic deformation and fatigue of a TiNi shape-memory alloy wire subjected to rotating bending," Journal of engineering materials technology, vol. 120, no. 1, pp. 64-70, 1998. [56] H. Tobushi, T. Hachisuka, S. Yamada, and P. H. Lin, "Rotating-bending fatigue of a TiNi shape-memory alloy wire," in ICF 9-Sydney, Australia-1997, 1997. [57] 許益适, "步進馬達原理與應用," ed: 全華出版社, 1994. [58] 南台科技大學, "步進馬達之速度控制,", 2010. [59] Q. Huang and J. X. Ren, "Surface integrity and its effects on the fatigue life of the nickel-based superalloy GH33A," International Journal of Fatigue, vol. 13, no. 4, pp. 322-326, 1991. [60] K. Sobczyk, "Modelling of random fatigue crack growth," Engineering fracture mechanics, vol. 24, no. 4, pp. 609-623, 1986. [61] Y. C. Chiou, J. Z. Liu, and Y. T. Liang, "Micro crack detection of multi-crystalline silicon solar wafer using machine vision techniques," Sensor Review, vol. 31, no. 2, pp. 154-165, 2011. [62] C. H. Park, L. D. Tijing, Y. Yun, and C. S. Kim, "A novel electrical potential sensing method for in vitro stent fracture monitoring and detection," Bio-medical materials engineering, vol. 21, no. 4, pp. 213-222, 2011.
|