1. International Atomic Energy Agency, Current status of neutron capture therapy, IAEA-TECODOC-1223, Vienna, 2001.
2. W.A.G. Sauerwein, et al., Neutron Capture Therapy: Principles and Applications, Springer-Verlag, New York, 2012.
3. M.B. Chadwick, et al., “ENDF/B-VII.0: Next generation evaluated nuclear data library for nuclear science and technology”, Nucl. Data Sheets, vol. 107, pp. 2931-3060, 2006.
4. R.E. White, P.H. Barker, and D.M.J. Lovelock, “Measurement of Nuclear Reaction Q-values with High Accuracy: 7Li(p,n)7Be”, Metrologia, vol. 21, pp. 193-199, 1985.
5. S. Takayanagi, et al., “Neutron threshold measurements in the reactions 9Be(p,n)9B, 10B(p,n)10C, 11B(p,n)11C”, Nucl. Phys., vol. 29, pp. 494-502, 1961.
6. N. Metropolis and S. Ulam, “The Monte Carlo method”, J. Am. Stat. Assoc., Vol. 44(247), pp. 335-341, 1949.
7. D.B. Pelowitz, et al., MCNPX user’s manual, Version. 2.7.0, Los Alamos report LA-CP-11-00438, 2011.
8. C.N. Clubertson, et al., “In-phantom characterization studies at the Birmingham Accelerator-Generated epithermal Neutron Source (BAGINS) BNCT facility”, Appl. Rad. And Iso., vol. 61, pp. 733-738, 2004.
9. J.C. Yanch, et al., “Accelerator-based epithermal neutron beam design for neutron capture therapy”, Med. Phys., vol. 19(3), pp. 709-721, 1992.
10. H. Tanaka, et al., “Characteristic comparison between a cyclotron-based neutron source and KUR-HWNIF for boron neutron capture therapy”, Nucl. Instrum. Meth. B, vol. 267, pp. 1970-1977, 2009.
11. B. Bayanov, V. Belov, and S. Taskaev, “Neutron producing target for accelerator based neutron capture therapy”, J. Phys. Conf. Ser., vol. 41, pp. 460-465, 2006.
12. J.T. Goorley, W.S. Kiger, and R.G. Zamenhof, “Reference dosimetry calculations for neutron capture therapy with comparison of analytical and voxel models”, Med. Phys., Vol. 29(2), pp. 145-156, 2002.
13. International Commission on Radiation Units and Measurements, Photon, electron, proton and neutron interaction data for body tissues, ICRU-46, Tech. Rep., 1992.
14. C.L. Lee, et al., “A Monte Carlo dosimetry-based evaluation of the 7Li(p,n)7Be reaction near threshold for accelerator boron neutron capture therapy”, Med. Phys., Vol. 27(1), pp. 192-202, 2000.
15. M.S. Herrera, et al., “Treatment planning capability assessment of a beam shaping assembly for accelerator-based BNCT”, Appl. Rad. And Iso., Vol. 69, pp. 1870-1873, 2011.
16. R.G. Zamenhof, et al., “Boron neutron cature therapy for the treatment of cerebral gliomas. I: Theoretical evaluation of the efficacy of various neutron beams”, Med. Phys.,Vol. 2, pp. 47-60, 1975.
17. D.M. Minsky, A.J. Kreiner, and A.A. Valda, “AB-BNCT beam shaping assembly based on 7Li(p,n)7Be reaction optimization”, Appl. Rad. And Iso., Vol. 69, pp. 1668-1671, 2011.
18. D.A. Allen, T.D. Beynon, and S. Green, “Design for an accelerator-based orthogonal epithermal neutron beam for boron neutron capture therapy”, Med. Phys., Vol. 26(1), pp. 71-76, 1999.
19. D.A. Allen, et al., “Toward a final design for the Birmingham boron neutron capture therapy neutron beam”, Med. Phys., Vol. 26(1), pp. 77-82, 1999.
20. B. Montagnini, et al., “Spectrum shaping of accelerator-based neutron beams for BNCT”, Nucl. Instrum. Meth. A, Vol. 476, pp. 90-98, 2002.
21. W.S. Snyder, et al., “Estimates for absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom”, J. Nucl. Med. Suppl., Vol. 3, pp. 7-52, 1969.
22. H. Fukuda, et al., “Boron Neutron Capture Therapy of Malignant Melanoma Using 10B-Paraboronophenylalanine with Special Reference to Evaluation of Radiation Dose and Damage to the Normal Skin”, Radiat. Res., Vol. 138, pp. 435-442, 1994.
23. A.Z. Kiss, et al., “Measurements of relative thick target yields for PIGE analysis on light elements in the proton energy interval 2.4-4.2MeV”, J. Radioanal. Nucl. Ch., Vol. 89, pp. 123-141, 1985.
24. E. Forton, et al., “Overview of the IBA accelerator-based BNCT system”, Appl. Rad. And Iso., Vol. 67, pp. 262-265, 2009.
25. J.C. Yanch, X.L. Zhor, G.L. Brownell, “A Monte Carlo investigation of the dosimetric properties of monoenergetic neutron beams for neutron capture therapy”, Radiat. Res., Vol. 126, pp. 1-20, 1991.
26. 葉藍筠,「BNCT治療計畫程式THORplan在復發頭頸部腫瘤臨床試驗之經驗回饋」,國立清華大學,碩士論文,中華民國一百年27. Y.H. Liu, et al., “Neutron spectra measurement and comparison of the HFR and THOR BNCT beams”, Appl. Rad. And Iso., Vol. 67, pp. 137-140, 2009.
28. K.M. Bushby, et al., “Centiles for adult head circumference”, Arch. Dis. Child., Vol. 76, pp. 1286-1287, 1992.